Description
Features
Reviews
ON-OFF switch, product range: ON-OFF switch, type code: T5B, with black toggle and front plate, 6-pole, protection class: IP65, design: surface mounting, switching angle: 90 °, switching behavior: latching, front plate: 0-1, rated operating power AC-23A, 50 - 60 Hz 400 V: P = 30 kW, rated continuous current: Iu = 63 A, 4 unit(s), standards and regulations: IEC/EN 60947,0660, IEC/EN 60204, CSA, UL, load-break switch according to IEC/EN 60947-3
Property | Value |
Number of poles: | 6 |
Rated operating power at AC-23, 400 V: | 30 kW |
Number of auxiliary contacts as normally closed: | 1 |
Number of auxiliary contacts as normally open: | 1 |
Rated continuous current Iu: | 63 A |
Max. Rated operating voltage Ue at AC: | 690 V |
Version as EMERGENCY STOP device: | no |
Protection class (IP), front: | IP65 |
Connection type main circuit: | screw connection |
Device design: | Complete device in housing |
Design of the actuating element: | short rotary handle |
Suitable for floor mounting: | yes |
Conditional rated short-circuit current Iq: | 2 kA |
Motor drive integrated: | no |
Suitable for front mounting 4-hole: | no |
Version as maintenance/repair switch: | no |
Voltage release optional: | no |
Suitable for front mounting central: | no |
Suitable for intermediate installation: | no |
Suitable for distribution board installation: | no |
Version as main switch: | no |
Version as safety switch: | no |
Motor drive optional: | no |
Lockable: | no |
Version as reversing switch: | no |
Rated short-time withstand current Icw: | 1.3 kA |
Color of the actuating element: | black |
Rated operating voltage: | 690 V |
Rated operating power at AC-3, 400 V: | 22 kW |
Switching capacity at 400 V: | 30 kW |
Rated continuous current at AC-21, 400 V: | 63 A |
Number of Switch: | 1 |
Rated continuous current at AC-23, 400 V: | 63 A |
Protection class (NEMA): | 12 |
Features
HAB
T5B-4-15164/I4
Manufacturer
HAN
223021
GTIN
4015082230210
Connection type main circuit
Screw connection
Number of auxiliary contacts as normally open
1
Number of auxiliary contacts as normally closed
1
Number of switches
1
Designed as main switch
No
Designed as an EMERGENCY STOP device
No
Designed as a safety switch
No
Designed as a maintenance/repair switch
No
Version as reversing switch
No
Design of the actuating element
Short twist grip
Conditional rated short-circuit current Iq
2kA
Rated operational power at AC-23, 400 V
30kW
Rated operational power at AC-3, 400 V
22kW
Rated operating voltage
690V
Rated continuous current Iu
63 A
Rated continuous current at AC-21, 400 V
63 A
Rated continuous current at AC-23, 400 V
63 A
Rated short-time withstand current Icw
1.3kA
Color of the actuator
Black
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting Central
No
Suitable for distribution board installation
No
Suitable for intermediate construction
No
Device type
Complete device in housing
Max. rated operating voltage Ue at AC
690V
Motor drive integrated
No
Motor drive optional
No
Number of poles
6
Switching capacity at 400 V
30kW
Protection class (IP), front
IP65
Protection class (NEMA)
12
Voltage release optional
No
Lockable
No
No reviews yet — your comment may be first.
All reviews 0