Type of voltage of the supply voltage
Supply voltage
Max. fluorescent lamp load
Manufacturer
In stock
€63.05
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

With 4 independent contacts, 1 normally open contact each, potential-free 16A/250V AC, 230V LED lamps up to 600W, incandescent lamps 2000W. Stand-by loss only 0.03-0.4 watts. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 2 division units = 36mm wide, 58mm deep. With the patented Eltako Duplex technology (DX), 3 of the 4 normally potential-free contacts can still switch at zero crossing when switching 230V AC 50Hz, thus drastically reducing wear. To do this, simply connect the N conductor to the terminal (N) and the outer conductors to 1(L), 3(L) or 5(L). This results in an additional stand-by loss of only 0.1 watts. If the contact is used to control switching devices which do not themselves switch at zero crossing, (N) should not be connected as the additional closing delay would otherwise have the opposite effect. Local universal control voltage 8..230V UC. With additional universal voltage control inputs central on and off for 8..230V UC, galvanically isolated from the local control inputs. With additional group control inputs on and off for 8..230V UC. Same potential as the local control inputs. Groups of these impulse switches can be controlled separately in a central control system via the group control inputs. Supply voltage same as the local control voltage. By using bistable relays, there is no coil power loss and no heating as a result, even when switched on. After installation, wait for the automatic short synchronization before connecting switched consumers to the mains. Central commands always have priority, the local control inputs are blocked during the central command. If the supply voltage fails, the device is switched off in a defined manner. Using the upper rotary switch, this impulse switch can be fully or partially excluded from the central control: ZE+ZA = centrally on and centrally off effective, ZE = only centrally on effective, ZA = only centrally off effective, ZE+ZA = no central control effective. The middle rotary switch is used to preselect the functions of the lower rotary switch for ES and ER. ER is used to select the bracket functions. If BM is selected, it can be controlled with a motion detector; function as per the operating instructions. Not suitable for feedback with the switching voltage of a dimmer switch. Only use the ESR12DDX-UC, ESR12NP-230V+UC or ESR61NP-230V+UC relays for this. The lower rotary switch can be used to choose between 18 functions: ON = permanently ON. 4xS = 4-way impulse switch, each with 1 normally open contact, control inputs A1, A3, A5 and A7. (4xR) = 4-way switching relay with 1 normally open contact each, control inputs A1, A3, A5 and A7. 4S = impulse switch with 4 normally open contacts. (4R) = switching relay with 4 normally open contacts. 2S/WS = impulse switch with 3 normally open contacts and 1 normally closed contact. (2R/WR) = switching relay with 3 normally open contacts and 1 normally closed contact. 2WS = impulse switch with 2 normally open contacts and 2 normally closed contacts. (2WR) = switching relay with 2 normally open contacts and 2 normally closed contacts. SSa = series switch 2 + 2 normally open contacts with switching sequence 0-2-2+4-2+4+6, feedback 8. (4RR) = quiescent current relay with 4 normally closed contacts. SSb = series switch 2 + 2 normally open contacts with switching sequence 0-2-2+4-2+4+6-2+4+6+8. (EW) = On-wiping relay with 3 NO contacts and 1 NC contact, wiping time 1s. GS = Group switch. Switching sequence 0-2-0-4-0-6-0, feedback 8. (AW) = Off-wiping relay with 3 NO contacts and 1 NC contact, wiping time 1s. RS = Switch with 4 NO contacts, A1 = set and A3 = reset control input. (GR) = Group relay 1 + 1 + 1 +1 NO contact. 3xS+ = 3-way impulse switch with 1 NO contact each + feedback 8, control inputs A1, A3 and A5. (3xR+) = 3-way switching relay with 1 normally open contact each + feedback 8, control inputs A1, A3 and A5.

Property Value
Width in division units: 1
Rated switching current: 16 A
Control voltage 1: 8 to 253 V
Control voltage type 1: AC
Control voltage 2: 230 to 10 V
Control voltage type 2: DC
Installation depth: 58 mm
Function: electronic for central control
Mounting type: DIN rail
Frequency of control voltage 1: 50 Hz
Frequency of control voltage 2: 50 Hz
Type of supply voltage: AC/DC
Supply voltage: 230 V
Max. incandescent lamp load: 2000 W
Max. fluorescent lamp load: 1000 VA
Max. fluorescent lamp load (duo circuit): 1000 VA
Max. fluorescent lamp load (parallel compensated): 500 VA
Max. switching current (cos phi = 0.6): 8 A
Number of contacts as normally open: 1
Features
Type of voltage of the supply voltage
Supply voltage
Max. fluorescent lamp load
Manufacturer
HAN
GTIN
Number of contacts as normally open
Width in pitch units
Installation depth
Function
Mounting type
Supply voltage
No reviews yet — your comment may be first.
All reviews 0
general rating