Clock generator starting with pulse, 1 changeover contact potential-free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 2000W*. Standby loss only 0.02-0.4 watts. Modular devices for mounting on DIN-EN 60715 TH35 rail. 1 division unit = 18mm wide, 58mm deep. With the same time base, t1 and t2 can be set separately using a second multiplier. With the patented Eltako Duplex technology (DX), the normally potential-free contacts can still switch at zero crossing when switching 230V AC 50Hz, thereby drastically reducing wear. To do this, simply connect the N conductor to terminal (N) and L to 15 (L). This results in an additional standby loss of just 0.1 watt. Universal control voltage 8..230V UC. Supply voltage same as the control voltage. Time range 0.1 seconds to 40 hours. By using a bistable relay, there is no coil power loss and no heating as a result, even when switched on. After installation, wait for the short automatic synchronization before connecting the switched consumer to the mains. The LED under the large rotary switch provides information about the contact position as the time elapses. It flashes as long as the working contact 15-18 is open (15-16 closed) and lights up constantly as long as the working contact 15-18 is closed (15-16 open). The time base T is set using the locking rotary switch T. The base values available are 0.1 second, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is the time base multiplied by the multiplier. The multiplier xT is set using the locking rotary switch xT and is between 1 and 10. This allows times between 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10) to be set. * The maximum load can be used from a delay or cycle time of 5 minutes. For shorter times, the maximum load is reduced as follows: Up to 2 seconds to 15%, up to 2 minutes to 30%, up to 5 minutes to 60%.
Property | Value |
Width in division units: | 1 |
Number of switches: | 1 |
Installation height: | 58 mm |
Mounting type: | DIN rail |
Function: | Clock generator starting with pulse |
Supply voltage: | 8 to 230 V |
Switching capacity of incandescent lamps: | 2000 W |
Switching capacity of inductive fluorescent lamps: | 1000 VA |
Switching capacity of DUO fluorescent lamps: | 1000 VA |
1. Time range: | 0.1 to 40 |
Control voltage 1: | 8 to 230 V |
Control voltage type 1: | AC/DC |
Frequency of control voltage 1: | 50 Hz |
Switching capacity of fluorescent lamps in parallel: | 500 VA |
Type of supply voltage: | AC/DC |
Type of operation: | analog with single function |
1. Time range unit: | Minutes/Hours |