1 normally open contact not potential-free 16A/250V AC, 230V LED lamps up to 600W, ESL up to 200W, incandescent lamps up to 2300W. Control voltage 230V and/or 8..230V UC. Switch-off warning and button permanent light can be switched on. Standby loss only 0.5 watts. With ESL optimization and multifunction. The functions and times are entered using the MODE and SET buttons in accordance with the operating instructions and shown digitally on the LC display. A key lock is possible. Contact switching at zero crossing to protect the contacts and lamps. In particular, this extends the service life of energy-saving lamps. The noiseless electronics do not bother the most sensitive ear - in contrast to many synchronous motors with mechanical gears. By using a bistable relay, there is no coil power loss and no heating as a result, even when switched on. After installation, wait for the automatic short synchronization before connecting the switched consumer to the mains. Control, supply and switching voltage 230V. Additionally with galvanically isolated universal control voltage 8..230V UC. For 3- and 4-wire circuits, can be switched on later, with attic lighting for 4-wire circuits. Automatic detection of the circuit type. Glow lamp current up to 50mA, depending on the ignition voltage of the glow lamps. Exact time setting 1 to 99 minutes. Separate continuous light button with the protruding SET button in the functions TLZ, ESV, ES and ER. With motion detector control input BM, which converts the input signal into a control pulse in the TLZ function.
Property | Value |
Width in division units: | 1 |
Off delay: | 1 min |
Function: | electronic with multifunction |
Mounting type: | DIN rail |
Control voltage 1: | 230 V |
Rated switching current: | 16 A |
Control voltage type 1: | AC |
Current surge function selectable: | yes |
Control voltage 2: | 8 to 230 V |
Control voltage type 2: | AC/DC |
Frequency of control voltage 1: | 50 Hz |
Circuit type: | 3- and 4-wire circuit |
Switch-off warning: | flickering |
Follow-up: | switchable + continuous light + time extension |
Type of supply voltage: | AC |
Installation depth: | 58 mm |
Max. switching current (cos phi = 0.6): | 4 A |
Button glow lamp current: | 50 mA |
Supply voltage: | 250 V |
Max. incandescent lamp load: | 2300 W |
Max. Fluorescent lamp load: | 1000 VA |
Max. fluorescent lamp load (duo circuit): | 1000 VA |
Max. fluorescent lamp load (parallel compensated): | 500 VA |
Number of contacts as normally open: | 1 |