Mobile AC meter with protective contact plug and protective contact coupling. With additional personal protection intermediate switch PRCD 30mA. Suitable for indoor and outdoor use. Maximum current 16A. Standby loss only 0.4 watts. Housing dimensions 110x70x35mm, connecting cable 1.5m (incl. plug and coupling). Accuracy class B (1%). This mobile AC meter measures the active energy based on the current flowing between the input and the output. The self-consumption of only a maximum of 0.4 watts of active power is not measured and not displayed. Every 30 seconds the display switches for 5 seconds from the accumulated active energy in kWh to the current consumption in watts. The starting current is 20mA. The display can only be read when there is a power supply. However, the consumption is stored non-volatilely and is immediately displayed again after a power failure. The digital display has 7 digits. Up to 99999.99 kWh, two decimal places are displayed. From 100000.0 kWh, only one. The power consumption is displayed with an LED that flashes 2000 times per kWh. The personal protection intermediate switch PRCD detects fault currents that occur, for example, when touching a faulty electrical device and interrupts the current so quickly that life-threatening accidents can be prevented. It also has an undervoltage release that switches off if the mains voltage fails. With function display and test circuit. Technical data: Operating voltage: 230V, 50Hz, extended range -20%/+15%. Rated current: 16A. Meter current range: Reference current Iref (limit current Imax): 0.25-5(32)A. Own consumption of active power: 0.4W. Display: LC display 7 digits, of which 1 or 2 are decimal places. Accuracy class for ±1%: B. Starting current according to accuracy class B: 20mA. Operating temperature: -25/+55°C. Protection class housing: lP54, plug and coupling: IP44. Cable cross-section: 3x2.5mm². Cable length including plug and coupling: 1.50m. Mechanical ambient conditions: Class M1. Electromagnetic ambient conditions: Class E2. Personal protective equipment (PRCD). Protection class: IP66. Tripping current: 30mA. Tripping time:
Property | Value |
Calibrated: | yes |
Pole type: | 1-phase |
Meter type: | electronic |
Display type: | digital |
Accuracy class: | B |
Maximum current (Imax): | 16 A |
Nominal voltage (Un) NL: | 230 V |
Pulse rate: | 2000 Imp/kWh (kvarh) |
Protection class (IP): | IP54 |
Frequency: | 50 Hz |
Tariff version: | Single tariff |
Energy type: | Active power |
Nominal current (In): | 5 A |
Version: | Direct measurement |
With lock code: | no |
Number of digits: | 7 |
Suitable for: | Reference |
Backstop: | yes |
Approval: | Measuring Instruments Directive |
Pulse output: | optical |
Interface design: | other |