Multifunctional time relay with 10 functions, 1 changeover contact potential-free 10A/250V AC, 230V LED lamps up to 400W, incandescent lamps 2000W*, with DX technology. Bidirectional. Standby loss only 0.4 watts. Modular device for mounting on DIN-EN 60715 TH35 mounting rail. 1 division unit = 18mm wide, 58mm deep. Connection to the Eltako RS485 bus. Cross-wiring of bus and power supply with jumper. Wireless window/door contacts (FTK) can be taught in with the function of normally open or normally closed when the window is open. If a direction button is taught in, a function (e.g. TI) can be started with the upper button (START) and stopped with the lower button (STOP). With the patented Eltako Duplex technology, the normally potential-free contacts can still switch at zero crossing when switching 230V AC 50Hz, thereby drastically reducing wear. To do this, simply connect the N conductor to terminal (N) and L to K(L). This results in an additional standby loss of just 0.1 watt. If the supply voltage fails, both contacts switch off. When the supply voltage returns, contact 1 closes. Times can be set between 0.5 seconds and 10 hours. The upper and middle rotary switches are used to teach in and then set the time. T is the time base and xT is the multiplier. The function is selected with the lower rotary switch: RV = release delay. AV = response delay. TI = clock generator starting with pulse. TP = clock generator starting with pause. IA = pulse-controlled response delay (e.g. automatic door opener). EW = pulse-on switch. AW = pulse-off switch. ARV = response and release delay. ON = permanently ON. OFF = permanently OFF. The LED under the upper rotary switch accompanies the teach-in process in accordance with the operating instructions and indicates control commands during operation by flashing briefly. * The maximum load can be used from a delay or cycle time of 5 minutes. For shorter times, the maximum load is reduced as follows: Up to 2 seconds to 15%, up to 2 minutes to 30%, up to 5 minutes to 60%.
Property | Value |
Width in division units: | 1 |
Max. Number of switching outputs: | 1 |
Mounting type: | REG |
Protection class (IP): | IP20 |
Max. switching capacity: | 2000 W |
KNX bus system: | no |
Max. Switching current: | 10 A |
Bus system radio bus: | yes |
Bus system Powernet: | no |
With bus connection: | yes |
Bus system LON: | no |
Other bus systems: | without |
On-site/manual operation: | no |
With LED display: | no |
Rated current: | 10 A |
Rated operating voltage: | 12 V |
Different phases can be connected: | no |
Modular expansion option: | no |
KNX radio bus system: | no |
Bidirectional radio: | yes |
Removable bus module: | yes |
Output power: | 2000 W |