Power relay for circuit boards for use in inverters, 2 normally open contacts for 50 A (AC1), max. inrush current 150 A - 5 ms, bridge contacts, contact material AgSnO2, contact opening greater than 3 mm, nominal voltage 400 V AC, max. switching voltage 690 V AC, max. switching capacity AC1/AC7a (400 V AC) 20,000 VA, max. switching capacity AC15 (230 V AC) 2,300 VA, 1-phase motor load, AC3 operation (230 V AC) 2 kW, minimum switching load 1000 mW at 10 V/10 mA, ambient temperature -40 to + 70 ° C at max. continuous contact current and control within the operating range, ambient temperature up to 85 ° C in energy saving mode at. max. continuous contact current, control range and operation in the holding voltage range, nominal coil power 1.7 W, minimum holding power 0.17 W, coil voltage 12 V DC, standard operation: operating range 0.9 to 1.1 x Un, in energy saving mode: 0.95 to 2.5 x Un (less than 1 s), holding voltage range 0.32 to 0.65 x Un, minimum holding power 0.17 W, distance between circuit board and relay base plate for air circulation is 1.5 mm.
Property | Value |
Number of contacts as normally open: | 2 |
Rated control supply voltage Us at DC: | 12 V |
Voltage type for actuation: | DC |
Design of the electrical connection: | PCB connection |
Drive, polarity: | unpolarized |
Height: | 62 mm |
Width: | 33 mm |
Depth: | 51.5 mm |
Switching behavior of the drive: | monostable |
Type of switching contact: | single contact |
With positively guided contacts: | no |
With removable terminals: | no |
Complete device with base: | no |
Protection class (IP): | IP40 |
Rated current: | 50 A |
With LED display: | no |