Compact circuit breaker (MCB) according to EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. Alternatively, a RESTART reclosing device RM TOP, a RESTART remote operator CM or two auxiliary devices can be installed on the left side. With label window on the device. Connection (max): flexible 16qmm, rigid 10qmm with insulated plug-in protection. The connection screws can be provided with a sealable cover (order accessories separately). Space-saving series with two protected poles or one protected pole with switched neutral conductor in one division unit. The switching lever can be sealed when switched on or off, or can be locked with a lever lock (order accessories separately) for a padlock.
Property | Value |
Triggering characteristics: | C |
Rated current: | 10 A |
Rated voltage: | 400 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 2 |
Number of poles (total): | 4 |
Energy limitation class: | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 72 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 6 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 6 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 6 kA |
Pollution level: | 3 |
Switching neutral conductor: | no |
Number of protected poles: | 4 |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 10 mm² |
Connectable conductor cross-section, single-wire: | 16 mm² |
Features
HAB
(MCB) Compact C-10A 6kA 4-pole 2TE
Manufacturer
HAN
GW90286
GTIN
8011564056930
Connectable conductor cross-section solid
16 mm²
Connectable conductor cross-section stranded
10 mm²
Number of protected poles
4
Trigger characteristics
C
Rated insulation voltage Ui
500V
Rated switching capacity Icn according to EN 60898 at 230 V
6kA
Rated switching capacity Icn according to EN 60898 at 400 V
6kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
6kA
Rated voltage
400V
Rated impulse withstand voltage Uimp
4kV
Rated current
10A
Width in pitch units
2
Installation depth
72 mm
Energy limitation class
3
Frequency
50 to 60 Hz
Switching neutral conductor
No
Number of poles (total)
4
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
3
Additional equipment possible
Yes
Overvoltage category
3