Miniature circuit breaker (MCB) according to EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. Alternatively, a RESTART restart device RM TOP, a RESTART remote operator CM or two auxiliary devices can be installed on the left side. With label window on the device. Connection (max): 35 mm² with insulated plug-in protection. The connection screws can be provided with a sealable cover (order accessories separately). The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock for a padlock. The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock for a padlock.
Property | Value |
Triggering characteristic: | C |
Rated current: | 32 A |
Rated voltage: | 400 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 2 |
Number of poles (total): | 2 |
Additional equipment possible: | yes |
Overvoltage category: | 3 |
Installation depth: | 72 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 25 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 30 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 20 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 20 kA |
Pollution degree: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 2 |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 35 mm² |
Connectable conductor cross-section, single-wire: | 35 mm² |
Features
HAB
(MCB) C-32A 15kA 2-pole 2TE
Manufacturer
HAN
GW92850
GTIN
8011564059054
Connectable conductor cross-section solid
35 mm²
Connectable conductor cross-section stranded
35 mm²
Number of protected poles
2
Trigger characteristics
C
Rated insulation voltage Ui
500V
Rated switching capacity Icn according to EN 60898 at 230 V
25kA
Rated switching capacity Icn according to EN 60898 at 400 V
20kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
30kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
20kA
Rated voltage
400V
Rated impulse withstand voltage Uimp
4kV
Rated current
32 A
Width in pitch units
2
Installation depth
72 mm
Frequency
50 to 60 Hz
Switching neutral conductor
No
Number of poles (total)
2
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
2
Additional equipment possible
Yes
Overvoltage category
3