Circuit breaker (MCB) in accordance with EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. Up to 2 additional devices can be attached on the left. With label window on the device. Connection (max): flexible 50 mm², rigid 70 mm² with built-in box terminals. With the included conversion kit, the box terminals can be exchanged for a connection for ring cable lugs (hole for M6 screws / width max. 17 mm). For a control line tap, a flat plug connection (width 4.8 mm, thickness 0.5 mm) is integrated for each pole on the incoming and outgoing side. The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock for a padlock.
Property | Value |
Triggering characteristic: | C |
Rated current: | 100 A |
Rated voltage: | 400 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 4.5 |
Number of poles (total): | 3 |
Additional equipment possible: | yes |
Overvoltage category: | 4 |
Installation depth: | 72 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 20 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 16 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 10 kA |
Pollution level: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 3 |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 6 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 50 mm² |
Connectable conductor cross-section, solid: | 70 mm² |
Features
HAB
High performance C-100A 10kA 3-pole 4.5TE
Manufacturer
HAN
GW93338
GTIN
8011564196315
Connectable conductor cross-section solid
70 mm²
Connectable conductor cross-section stranded
50 mm²
Number of protected poles
3
Trigger characteristics
C
Rated insulation voltage Ui
500V
Rated switching capacity Icn according to EN 60898 at 230 V
10kA
Rated switching capacity Icn according to EN 60898 at 400 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
20kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
16kA
Rated voltage
400V
Rated impulse withstand voltage Uimp
6kV
Rated current
100A
Width in pitch units
4.5
Installation depth
72 mm
Frequency
50 to 60 Hz
Switching neutral conductor
No
Number of poles (total)
3
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
2
Additional equipment possible
Yes
Overvoltage category
4
No reviews yet — your comment may be first.
All reviews 0