Circuit breaker (MCB) in accordance with EN60898-1, with time-delayed thermal overload release and electromagnetic short-circuit release. Up to 2 additional devices can be attached on the left. With label window on the device. Connection (max): flexible 50 mm², rigid 70 mm² with built-in box terminals. With the included conversion kit, the box terminals can be exchanged for a connection for ring cable lugs (hole for M6 screws / width max. 17 mm). For a control line tap, a flat plug connection (width 4.8 mm, thickness 0.5 mm) is integrated for each pole on the incoming and outgoing side. The switching lever can be sealed in the switched-on and off state or can be locked with a lever lock for a padlock.
Property | Value |
Triggering characteristic: | C |
Rated current: | 80 A |
Rated voltage: | 400 V |
Type of voltage: | AC |
Frequency: | 50 to 60 Hz |
Width in pitch units: | 6 |
Number of poles (total): | 4 |
Additional equipment possible: | yes |
Overvoltage category: | 4 |
Installation depth: | 72 mm |
Protection class (IP): | IP20 |
Rated switching capacity Icn according to EN 60898 at 230 V: | 10 kA |
Rated switching capacity Icu according to IEC 60947-2 at 230 V: | 20 kA |
Rated switching capacity Icu according to IEC 60947-2 at 400 V: | 16 kA |
Rated switching capacity Icn according to EN 60898 at 400 V: | 10 kA |
Pollution degree: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 4 |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 6 kV |
Ambient temperature during operation: | -25 to 60 °C |
Connectable conductor cross-section, stranded: | 50 mm² |
Connectable conductor cross-section, single-wire: | 70 mm² |
Features
HAB
High performance C-80A 10kA 4-pole 6TE
Manufacturer
HAN
GW93347
GTIN
8011564196339
Connectable conductor cross-section solid
70 mm²
Connectable conductor cross-section stranded
50 mm²
Number of protected poles
4
Trigger characteristics
C
Rated insulation voltage Ui
500V
Rated switching capacity Icn according to EN 60898 at 230 V
10kA
Rated switching capacity Icn according to EN 60898 at 400 V
10kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V
20kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V
16kA
Rated voltage
400V
Rated impulse withstand voltage Uimp
6kV
Rated current
80A
Width in pitch units
6
Installation depth
72 mm
Frequency
50 to 60 Hz
Switching neutral conductor
No
Number of poles (total)
4
IP protection)
IP20
Voltage type
AC
Ambient temperature during operation
-25 to 60 °C
Degree of contamination
2
Additional equipment possible
Yes
Overvoltage category
4