High-efficiency wet rotor pump for use in heat pump systems, particularly in the consumer circuit (heating and cooling) and in the brine circuit thanks to cataphoresis coating and fixed speed levels. Control types for optimal load adaptation can be preselected via the control button: fixed speed levels (I, II III) and constant differential pressure control (pc) 3-stage, optional control via external input signal possible (signal cable not included). Venting function available. Max. delivery head 8.4 m with a throughput of 1.1 m3/h, volume flow max. 3.5 m3/h with a delivery head of 2.2 m Max. pressure level PN 10 Energy efficiency EEI 0.21. Pitch 180 mm Connection voltage: 1/N/PE ~230 V, 50 Hz. Dimensions: H x D x W: 180 x 138 x 94 mm. Connection cable load 1.5 m and seals (2x) included.
Property | Value |
Protection class (IP): | IPX4D |
Material of the blower wheel/impeller: | Polypropylene (PP) |
Frequency: | 50/60 Hz |
Absorbed motor power (P1) per motor: | 75 kW |
Rated current: | 0.66 A |
Electrical connection: | Connection cable with Plug |
Insulation class according to IEC: | F |
Motor speed control: | built-in |
Type of speed control: | continuously variable |
Pump switching: | other |
Double pump: | no |
Installation length: | 180 mm |
Energy efficiency index (EEI): | 0.21 |
Material of pump housing: | cast iron |
Material quality of blower wheel/impeller: | PP-GF |
Volume flow (BEP): | 3.5 m³/h |
Delivery head at volume flow (BEP): | 80 kPa |
Max. delivery head: | 8.5 m |
Max. Working pressure: | 10 bar |
Cable length: | 1.5 m |
Rated voltage: | 220 to 240 V |
Number of phases: | 1 |
Communication: | built-in and prepared |
Wireless standard Bluetooth: | no |
Wireless standard WLAN 802.11: | no |
Wireless standard 5G: | no |
Interface signal 0-10 V / 2-10 V: | no |
Interface signal 0-20 mA / 4-20 mA: | no |
Interface PT100 / PT1000 / PTC: | no |
Interface Pulse Width Modulation (PWM): | yes |
Interface Pulse counter: | no |
Potential-free switching contact: | no |
With communication interface RS-485: | no |
With communication interface RS-232: | no |
Supports protocol for EtherNet/IP: | no |
Supports protocol for KNX: | no |
Supports protocol for PROFIBUS: | no |
Supports protocol for PROFINET IO: | no |
Supports protocol for CAN/CANOpen: | no |
Supports protocol for Modbus TCP: | no |
Supports protocol for Modbus RTU: | no |
Supports protocol for BACnet MS/TP: | no |
Supports protocol for BACnet IP: | no |
Supports protocol for LON/LONWorks: | no |
Supports protocol for LIN Bus: | no |
Medium temperature (continuous operation): | -20 to 110 °C |
Ambient temperature: | -20 to 70 °C |
Inlet connection: | External thread (metric) |
Nominal diameter, inlet connection: | 1 1/2 inch (40) |
Outlet connection: | External thread (metric) |
Nominal diameter, outlet connection: | 1 1/2 inch (40) |