Description
Features
Reviews
Analog multimeter for electrical applications Class 2, 5. Class 2, 5 - compact, proven design. CE marking Measurement category CAT II Housing protection class IP 40 Voltage measurement 0 .. 0.15 / 0 .. 0.5 V = 0 .. 1.5 / 5 / 15 / 50 / 150 / 500 V = / ~ Input resistance 20 k / V =, 4 k / V ~ Current measurement 0 .. 50 mA =, 0 .. 1.5 / 15 / 150 mA / 1.5 / 15 A = / ~ Resistance measurement: 1 .. 1 M (4 ranges) Level: -15 .. +56 dB (6 ranges) Accuracy: Class 2.5 Dimensions: 92 x 126 x 45 mm Weight: approx. 0.25 kg without battery Battery: 1.5 V IEC LR 6 (Mignon, AA). 1 analog multimeter (without battery, without cable set)1 operating manual
| Property | Value |
| Max. Voltage measuring range AC: | 500 V |
| Measuring range selection: | manual |
| Display: | analog |
| With level measurement (dB): | yes |
| Frequency measurement: | no |
| Capacitance measurement: | no |
| Analog bar display: | no |
| Multiple display: | no |
| Smallest resolution for alternating voltage: | 10 mV |
| Max. voltage measuring range for DC: | 500 V |
| Smallest resolution for direct voltage: | 1 mV |
| Max. current measuring range for AC: | 15 A |
| Smallest resolution for alternating current: | 10 µA |
| Max. current measuring range for DC: | 15 A |
| Smallest resolution for direct current: | 1 µA |
| Max. Resistance measuring range: | 1 MOhm |
| Lowest resistance resolution: | 1 Ohm |
| Continuity test/diode test: | no |
| Relative value measurement: | no |
| Inductance measurement: | no |
| Conductance measurement: | no |
| Instantaneous value memory (data hold): | no |
| Maximum value memory: | no |
| Minimal value memory: | no |
| Peak value memory: | no |
| True RMS measurement (TRMS): | no |
| Duty cycle measurements: | no |
| Measured value memory: | no |
| Interface: | no |
| Measuring circuit category: | CAT II |
| Analog bar display analog/logarithmic: | no |
| Bluetooth interface: | no |
| Speed measurement: | no |
| Continuity test: | no |
| Explosion-tested version: | no |
| IR interface: | no |
| Cable length measurement: | no |
| Smallest resolution capacitance: | 1 µF |
| Power and energy measurement: | no |
| Line symmetry test for two-wire connections abE: | no |
| Max. capacitance measuring range: | 200000 µF |
| Max. Voltage measuring circuit category: | 500 V |
| Milliohm measurement with 4-wire technology (Kelvin connection): | no |
| Nominal test voltage 10 V: | no |
| Nominal test voltage 100 V: | no |
| Nominal test voltage 1000 V: | no |
| Nominal test voltage 250 V: | no |
| Nominal test voltage 50 V: | no |
| Nominal test voltage 500 V: | no |
| Harmonics analysis/Power Quality: | no |
| Automatic circuit breaker: | no |
| Temperature measurement RTD: | no |
| Temperature measurement TC: | no |
Features
Explosion-tested version
No
HAB
M101A MetraHit2A
Manufacturer
HAN
M101A
GTIN
4012932117271
Interface
No
No reviews yet — your comment may be first.