High-end TRMS system multimeter with 60,000 digits digital display and IR interface without fuse. The METRAHIT EU PRO is a special multimeter for energy suppliers (energy utilities). The high-end TRMS multimeters METRAHIT EU PRO are absolutely robust and reliable digital multimeters developed for professional use. The devices have an attractive design with housings made of impact-resistant plastic and are technically state of the art. The METRAHIT EU PRO is a special multimeter for energy suppliers (energy utilities) without a fuse for measuring current transformers in the energy supply. State-of-the-art quality measuring instruments with unique precision: 60,000 digits and 0.05% basic accuracy offer the highest level of result reliability. The latest technology ensures maximum safety. The variety of functions covers a wide range of demanding measuring tasks. The innovative and ergonomic design inspires every day. . TRMSAC, AC+DC measurement up to 20 kHz for voltage and currentWithout fuse to prevent any danger from interruption of current transformer circuitsAdjustable transformer factor with automatic calculation of the current value. Universally applicable in all areas of electrical engineering! True RMS measurement up to 20 kHz with 60,000 digits digital display and analogue scaleMeasurement of voltage and current, DC, AC and ACDC, dB, REL, resistance, temperature, frequency, continuity / diodesClip function for current measurement with transformers and sensorsAutomatic measurement range selection and measured value storageSafety for the user and the device in the measurement category CAT II up to 600V. The multimeter is particularly suitable for use in the energy supply. To prevent any danger from an interruption of the secondary circuit of the current transformer, there is no fuse in the current measuring circuit. The device is suitable for field use and has an internal mains-independent power supply. 21 multimeter functionsResolution ±60,000 digits, 4 6/7 digitsBasic accuracy ±0.05% (VDC)Voltage ACTRMS, voltage AC+DC TRMS, voltage DC, level dB, relative value REL, frequency (Hz, kHz), resistance, diode test, continuity test, current ACTRMS, current AC+DCTRMS, temperature with K thermocouplesAutorange current measurement from 1 mA to 10 A (16A) via a socketClip function for current measurement with converters and sensorsAdditional filter function and voltage measurement with reduced input resistance to limit interference, e.g. when measuring on frequency convertersAutomatic and manual measurement range selectionZero point setting ZEROAutomatic measured value storage DATA / MIN / MAXLarge, light blue illuminated display with extra large digits (15mm) and analog bar graph for dynamic processesSeparate battery and Fuse compartmentPatented automatic socket lock ABSMeasurement category 600 V CAT IIRubber protective cover to protect against shock and impact. DAkkS calibration certificate included36 months guarantee on material and manufacturing defects. 1 x multimeter1 pair of safety measuring leads (1.5 m) with 4 mm test probes, 1000 V CAT III, 600 V CAT IV (KS17-2)1 x hard case HC202 x batteries 1.5 V, type AA1 x short operating instructions in German/English1 x CD-ROM, contents: operating instructions in German and English1 x DAkkS calibration certificate1 x rubber protective cover
Property | Value | ||
Max. Voltage measuring range AC: | 1000 V | ||
Measuring range selection: | manual/automatic | ||
Display: | analog/digital | ||
With level measurement (dB): | yes | ||
Frequency measurement: | yes | ||
Capacitance measurement: | no | ||
Analog bar display: | yes | ||
Multiple display: | no | ||
Smallest resolution for alternating voltage: | 0.01 mV | ||
Max. voltage measuring range for DC: | 1000 V | ||
Smallest resolution for direct voltage: | 0.01 mV | ||
Max. current measuring range for AC: | 10 A | ||
Smallest resolution for alternating current: | 100 µA | ||
Max. current measuring range for DC: | 10 A | Smallest resolution for direct current: | 100 µA |
Max. Resistance measuring range: | 60 MOhm | ||
Lowest resistance resolution: | 0.01 Ohm | ||
Continuity test/diode test: | yes | ||
Relative value measurement: | yes | ||
Inductance measurement: | no | ||
Conductance measurement: | no | ||
Instantaneous value memory (data hold): | yes | ||
Maximum value memory: | yes | ||
Minimal value memory: | yes | ||
Peak value memory: | no | ||
True RMS measurement (TRMS): | yes | ||
Duty cycle measurements: | no | ||
Measured value memory: | no | ||
Interface: | yes | ||
Measuring circuit category: | CAT IV | ||
Analog bar display analog/logarithmic: | no | ||
Bluetooth interface: | no | ||
Speed measurement: | no | ||
Continuity test: | yes | ||
Explosion-tested version: | no | ||
IR interface: | yes | ||
Cable length measurement: | no | ||
Lowest resolution frequency: | 0.01 Hz | ||
Lowest resolution temperature: | 0.1 °C | ||
Power and energy measurement: | no | ||
Line symmetry test for two-wire connections abE: | no | ||
Max. frequency measuring range: | 300 kHz | ||
Max. voltage measuring circuit category: | 600 V | ||
Max. Temperature measuring range: | 1372 °C | ||
Milliohm measurement with 4-wire technology (Kelvin connection): | no | ||
Nominal test voltage 10 V: | no | ||
Nominal test voltage 100 V: | no | ||
Nominal test voltage 1000 V: | no | ||
Nominal test voltage 250 V: | no | ||
Nominal test voltage 50 V: | no | ||
Nominal test voltage 500 V: | no | ||
Harmonics analysis/Power Quality: | no | ||
Automatic circuit breaker: | no | ||
Temperature measurement RTD: | no | ||
Temperature measurement TC: | yes |