Multi- and milliohmmeter, insulation measuring device, winding tester and data logger for hybrid and electric drives. The METRAHIT IM E-DRIVE BT is a multi- and milliohmmeter, insulation measuring device, winding tester and data logger. Applications can be found in the service and diagnosis of electrical machines and systems, especially in the automotive industry, electrical engineering and aerospace technology. . An all-in-one device with 30,000 digits: milliohm and multimeter, data logger and insulation resistance and winding tester. Compact and multifunctional for field use: Can be used just as advantageously in the aircraft cockpit as in other cramped measuring locations where otherwise several individual devices have to be used. Milliohm measurement with 4-wire connection (Kelvin measurement) with 200 mA or 1A Insulation tester with test voltages from 50 to 1000 V Turn-to-turn test with 1000 V test voltage High-end TRMS multimeter with 100 kHz bandwidth. Safety-relevant tests for electrical devices, drives and installations with just one field-compatible deviceHigh-voltage system test according to UN ECE R100Insulation resistance measurement according to EN 61557-2 /0413-2Rlow installation test according to EN 61557-4 /0413-4Bonding test or potential equalization measurement, e.g. on the outer skin of the aircraft (lightning protection - discharge test/'wick test'). The multimeter is a portable, extremely robust multi-meter designed for field use. It is suitable for maintenance, service and diagnosis of electrical machines or drives and systems, e.g. in the automotive, avionics, energy or automation sectors.The all-in-one device is an insulation tester, milliohmmeter, short circuit tester and universal multimeter. It is ideal for safety testing and diagnostics on electric and hybrid vehicles as well as all types of electrical machines. In conjunction with an optional coil test adapter, it enables short circuit measurements. Insulation resistance measurement up to 3.1 GOhm with external voltage detection, test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V according to EN 61557-2 DAR: Dielectric absorption rate and PI: Polarization index 4-wire milliohm measurement with Kelvin connection and 200 mA or 1 A measuring current for precise measurement of the smallest resistances with 1 microOhm resolution 2-wire Rlo measurement with 200 mA test current according to EN 61557-4 Short circuit test with 1000 V test voltage and optional COIL adapter Multifunctional device True RMS measurement TRMSAC/AC+DC for current/voltage up to 10/100 kHz Low pass filter AC, AC+DC Direct current measurement Current measurement with clamp sensors: The transmission factor can be adjusted with CLIP from 1:1 to 1:1000 and is taken into account in the ampere display. Capacitance measurement Precision temperature measurement °C, °F for RTD and TC-K sensors Diode measurement (K flow up to 5.1 V) and continuity test Acoustic signaling Recording of min/max values, DATA Hold Data logger thanks to integrated memory and real-time clock, also for individual measured values The push/print function transfers measured values to the application software at the touch of a button Programmable sequences for test routines METRALOG APP for Android OS Color graphic display Modular power supply: Standard lithium quick-change battery, optional power module with USB interface, change without interrupting the measuring circuit thanks to the patented touch-protected module socket Automatic socket lock (ABS) for the power input Test probe with function keys START (ISO) and STORE Housing IP52, dust and drip-proof, replaceable rubber protective cover Interfaces: BT Bluetooth integrated - USB with optional power module Windows software IZYTRONIQ for documentation, creation of test reports and graphical evaluation of the measurements. All-in-one device: multimeter, insulation tester and milliohmmeter 4-wire
Property | Value | ||
Max. Voltage measuring range AC: | 1000 V | ||
Measuring range selection: | manual/automatic | ||
Display: | graphic | ||
With level measurement (dB): | no | ||
Frequency measurement: | yes | ||
Capacitance measurement: | yes | ||
Analog bar display: | yes | ||
Multiple display: | yes | ||
Smallest resolution for alternating voltage: | 0.01 mV | ||
Max. voltage measuring range for DC: | 1000 V | ||
Smallest resolution for direct voltage: | 0.01 mV | ||
Max. current measuring range for AC: | 1 A | ||
Smallest resolution for alternating current: | 0.01 µA | ||
Max. current measuring range for DC: | 1 A | Smallest resolution for direct current: | 0.01 µA |
Max. Resistance measuring range: | 30 MOhm | ||
Lowest resistance resolution: | 0.1 Ohm | ||
Continuity test/diode test: | yes | ||
Relative value measurement: | yes | ||
Inductance measurement: | no | ||
Conductance measurement: | no | ||
Instantaneous value memory (data hold): | yes | ||
Maximum value memory: | yes | ||
Minimal value memory: | yes | ||
Peak value memory: | no | ||
True RMS measurement (TRMS): | yes | ||
Duty cycle measurements: | yes | ||
Measured value memory: | yes | ||
Interface: | yes | ||
Measuring circuit category: | CAT IV | ||
Analog bar display analog/logarithmic: | no | ||
Bluetooth interface: | yes | ||
Speed measurement: | yes | ||
Continuity test: | yes | ||
Explosion-tested version: | no | ||
IR interface: | no | ||
Insulation resistance measuring range: | 0.0001 to 3000 MOhm | ||
Cable length measurement: | no | ||
Lowest resolution frequency: | 0.01 Hz | ||
Smallest resolution for capacitance: | 0.00001 µF | ||
Smallest resolution for temperature: | 0.1 °C | ||
Power and energy measurement: | no | ||
Line symmetry test for two-wire connections abE: | no | ||
Max. frequency measuring range: | 300 kHz | ||
Max. capacitance measuring range: | 300 µF | ||
Max. Voltage measuring circuit category: | 600 V | ||
Max. Temperature measuring range: | 1372 °C | ||
Milliohm measurement with 4-wire technology (Kelvin connection): | yes | ||
Nominal test voltage 10 V: | no | ||
Nominal test voltage 100 V: | yes | ||
Nominal test voltage 1000 V: | yes | ||
Nominal test voltage 250 V: | yes | ||
Nominal test voltage 50 V: | yes | ||
Nominal test voltage 500 V: | yes | ||
Harmonics analysis/Power Quality: | no | ||
Automatic circuit breaker: | no | ||
Temperature measurement RTD: | yes | ||
Temperature measurement TC: | yes |