+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager ACS916D RCD/MCB 1P+N 6kA B16A 0.01A A QC&QB

Brand:HAGER
To compare
To favorites
SKU:156201
Hager ACS916D RCD/MCB 1P+N 6kA B16A 0.01A A QC&QB
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€63.24
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 1P+N 6kA B characteristic 16A 10mA type A QC. Residual current circuit breaker with QuickConnect terminal according to DIN EN 60898-1,0641-11, on the outgoing circuit up to 20 A and on the incoming circuit up to 63 A. Contact protection DIN0106 Part 100, blue test button and residual current display. Easy individual removal from the phase busbar system. With symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: B
Rated current: 16 A
Rated residual current: 0.01 A
Rated voltage: 240 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Residual current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Protection class (IP): IP2X
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager FZ352 marshalling duct set light grey 2-field
Hager FZ352 marshalling duct set light grey 2-field
63.25
In stock
Hager FZ537 for FR/FG cabinets swivel lever
Hager FZ537 for FR/FG cabinets swivel lever
63.35
In stock
Hager Y12ST assembly package TRE retrofit
Hager Y12ST assembly package TRE retrofit
63.35
In stock
Hager UC41KG 600x250mm for wire mesh duct kit
Hager UC41KG 600x250mm for wire mesh duct kit
63.37
In stock
Hager VH24NC cavity wall distributor Volta IP30 2x12PLE
Hager VH24NC cavity wall distributor Volta IP30 2x12PLE
63.09
In stock