Residual current circuit breaker 4P 6kA C-13A 30mA Type A QC/QB. Residual current circuit breaker in accordance with DIN EN 61009-1 (VDE 0664-20) with overload protection of the neutral conductor through a 4-pole circuit breaker for 400 V three-phase circuits and a residual current protection circuit in a compact housing. QuickConnect spring terminal in accordance with DIN EN 60898-1 (VDE 0641-11), on the outgoing and incoming circuits, blue test button and residual current display. Easy individual removal from the phase busbar assembly through top and bottom top hat rail sliders. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.
Property | Value |
Triggering characteristic: | C |
Rated current: | 13 A |
Rated residual current: | 0.03 A |
Rated voltage: | 400 V |
Frequency: | 50 Hz |
Number of poles (total): | 4 |
Width in pitch units: | 4 |
Residual current type: | A |
Installation depth: | 70 mm |
Surge current strength: | 3 kA |
Protection class (IP): | IP2X |
Energy limitation class: | 3 |
Overvoltage category: | 3 |
Pollution degree: | 2 |
Switching neutral conductor: | no |
Number of protected poles: | 4 |
Type of voltage: | AC |
False tripping protection: | no |
Rated insulation voltage Ui: | 500 V |
Rated impulse withstand voltage Uimp: | 4 kV |
Rated short-circuit breaking capacity Icn according to EN 61009-1: | 6 kA |
Shutdown characteristics: | undelayed |
With locking device: | yes |
Ambient temperature during operation: | -25 to 40 °C |
Connectable conductor cross-section, single-wire: | 1 to 25 mm² |
Connectable conductor cross-section, stranded: | 1 to 16 mm² |
Features
Shutdown characteristics
Without delay
Rated short-circuit breaking capacity Icn according to EN 61009-1
6 kA
HAB
ADM463QC 4P 6kA C-13A 30mA Type A QC/QB
Manufacturer
HAN
ADM463QC
GTIN
3250611027980
Connectable conductor cross-section solid
1 to 25 mm²
Connectable conductor cross-section stranded
1 to 16 mm²
Number of protected poles
4
Trigger characteristics
C
Rated residual current
0.03A
Rated insulation voltage Ui
500V
Rated voltage
400V
Rated impulse withstand voltage Uimp
4kV
Rated current
13 A
Width in pitch units
4
Installation depth
70 mm
Energy limitation class
3
False trigger protection
No
Residual current type
A
Frequency
50Hz
With locking device
Yes
Switching neutral conductor
No
Number of poles (total)
4
IP protection)
IP2X
Voltage type
AC
Surge current strength
3kA
Ambient temperature during operation
-25 to 40 °C
Degree of contamination
2
Overvoltage category
3