+351 934 234 451‬
Leave a call order
Адрес:
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Schedule:
Get route

Hager ADS956D RCD/MCB 1P+N 6kA C6A 0.03A A QC&QB

Brand:HAGER
SKU:303506
Hager ADS956D RCD/MCB 1P+N 6kA C6A 0.03A A QC&QB
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€68.69
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description

Residual current circuit breaker 1P+N 6kA C characteristic 6A 30mA type A QC. Residual current circuit breaker in accordance with DIN0664-20 / EN61009-1 with QuickConnect terminal in accordance with DIN EN 60898-1,0641-11, on the outgoing circuit up to 20 A and on the incoming circuit up to 63 A. Contact protection in accordance with IP2x DIN0106 Part 100, blue test button and residual current display. Easy individual removal from the phase busbar system. With symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Trip characteristic: C
Rated current: 6 A
Rated residual current: 0.03 A
Rated voltage: 240 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Fault current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Protection class (IP): IP20
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristic: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
Reviews
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager ADS975D RCD/MCB 1P+N 6kA C25A 0.03A A QB
Hager ADS975D RCD/MCB 1P+N 6kA C25A 0.03A A QB
68.69
In stock
Hager ZM24C busbar universZ 12x10mm 4-field
Hager ZM24C busbar universZ 12x10mm 4-field
68.69
In stock
Hager EZD100 24-240V AC/DC time relay
Hager EZD100 24-240V AC/DC time relay
68.69
In stock
Hager EZF100 Off-delayed 24-240V time relay
Hager EZF100 Off-delayed 24-240V time relay
68.69