Hager ADS960D RCD/MCB 1P+N 6kA C10A 0.03A A QC&QB

Brand:HAGER
To compare
To favorites
SKU:156224
Hager ADS960D RCD/MCB 1P+N 6kA C10A 0.03A A QC&QB
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€67.86
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 1P+N 6kA C characteristic 10A 30mA type A QC. Residual current circuit breaker in accordance with DIN0664-20 / EN61009-1 with QuickConnect terminal in accordance with DIN EN 60898-1,0641-11, on the outgoing circuit up to 20A and on the incoming circuit up to 63A, contact protection in accordance with IP2x DIN0106 part 100, external blue test button and residual current display. Easy individual removal from the phase busbar system. With symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: C
Rated current: 10 A
Rated residual current: 0.03 A
Rated voltage: 240 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Residual current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Protection class (IP): IP2X
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager MES-RS45601 450x100x600 RAL9005 series base
67.86
In stock
Hager MCS340 circuit breaker 3-pole C40A 6kA QC 3M
Hager MCS340 circuit breaker 3-pole C40A 6kA QC 3M
67.83
In stock
Hager HTS150E SLS switch 1-pole 50A for busbar
Hager HTS150E SLS switch 1-pole 50A for busbar
67.82
In stock
Hager RFA100D replacement sensor head
Hager RFA100D replacement sensor head
67.78
In stock
Hager RFA101D replacement sensor head
Hager RFA101D replacement sensor head
67.78
In stock
Hager UC21TR0 300x250mm for LTS 160A kit
Hager UC21TR0 300x250mm for LTS 160A kit
67.75
In stock
Hager HTS150E2 SLS switch E-50A for busbar 1-pole L2
Hager HTS150E2 SLS switch E-50A for busbar 1-pole L2
67.74
In stock
Hager C-QTUN110 crossbar
Hager C-QTUN110 crossbar
68
In stock