+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager ADS963D RCD/MCB 1P+N 6kA C13A 0.03A A QC&QB

Brand:HAGER
To compare
To favorites
SKU:156220
Hager ADS963D RCD/MCB 1P+N 6kA C13A 0.03A A QC&QB
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€65.64
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 1P+N 6kA C characteristic 13A 30mA type A QC. Residual current circuit breaker in accordance with DIN0664-20 / EN61009-1 with QuickConnect terminal in accordance with DIN EN 60898-1,0641-11, on the outgoing circuit up to 20A and on the incoming circuit up to 63A, contact protection in accordance with IP2x DIN0106 part 100, external blue test button and residual current display. Easy individual removal from the phase busbar system. With symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: C
Rated current: 13 A
Rated residual current: 0.03 A
Rated voltage: 240 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Residual current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Protection class (IP): IP2X
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager UC41MG 600x250mm f. REG w 4x12 PLE kit
Hager UC41MG 600x250mm f. REG w 4x12 PLE kit
65.55
In stock
Hager MES-RS45401 450x100x400 RAL9005 series base
65.54
In stock
Hager UE21A0 module 300x250mm busbar
Hager UE21A0 module 300x250mm busbar
65.54
In stock
Hager TG029 surge protection 2-pole tebis
Hager TG029 surge protection 2-pole tebis
65.53
In stock
Hager MM505N motor protection switch 0, 63-1A 230/400V
Hager MM505N motor protection switch 0, 63-1A 230/400V
65.48
In stock
Hager MM506N motor protection switch 1, 0-1, 6A 230/400V
Hager MM506N motor protection switch 1, 0-1, 6A 230/400V
65.48
In stock
Hager MM507N motor protection switch 1, 6-2, 5A 230/400V
Hager MM507N motor protection switch 1, 6-2, 5A 230/400V
65.48
In stock