+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager ADS967D residual current circuit breaker 1P+N 127V 6kA C-16A 30mA Type A QC

Brand:HAGER
To compare
To favorites
SKU:305298
Hager ADS967D residual current circuit breaker 1P+N 127V 6kA C-16A 30mA Type A QC
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€65.12
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 1P+N 127V 6kA C-16A 30mA Type A QuickConnect. Residual current circuit breaker in accordance with DIN EN 61009-1 (VDE 0664-20) with QuickConnect terminal, on the outgoing circuit up to 20 A and on the incoming circuit up to 63 A, blue test button and residual current display. Easy individual removal from the phase busbar system. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: C
Rated current: 16 A
Rated residual current: 0.03 A
Rated voltage: 127 V
Frequency: 50 Hz
Number of poles (total): 2
Width in pitch units: 2
Fault current type: A
Installation depth: 68 mm
Rated breaking capacity according to IEC 60947-2: 6 kA
Surge current strength: 0.25 kA
Degree of protection (IP): IP20
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: yes
Number of protected poles: 1
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 6 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Number of protected poles
Trigger characteristics
Rated breaking capacity according to IEC 60947-2
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager FZ8916ES B1600 single RAL7035 eaves sheet
Hager FZ8916ES B1600 single RAL7035 eaves sheet
65.12
In stock
Hager FZ8916RL B1600 row left RAL7035 eaves sheet
Hager FZ8916RL B1600 row left RAL7035 eaves sheet
65.12
In stock
Hager FZ8916RM B1600 row center RAL7035 eaves sheet
Hager FZ8916RM B1600 row center RAL7035 eaves sheet
65.12
In stock
Hager FZ8916RR B1600 row right RAL7035 eaves sheet
Hager FZ8916RR B1600 row right RAL7035 eaves sheet
65.12
In stock
Hager UC22BART 300x500mm BSA rt kit
Hager UC22BART 300x500mm BSA rt kit
65.01
In stock
Hager LZ152 prism terminal set NH2 120-240mm
Hager LZ152 prism terminal set NH2 120-240mm
64.99
In stock
Hager MES-QP45 1-piece for width 450mm cross profile
Hager MES-QP45 1-piece for width 450mm cross profile
64.99
In stock