Hager AFX460D FI/LS switch 4-pole 10kA C10A 0.3A A

Brand:HAGER
To compare
To favorites
SKU:303539
Hager AFX460D FI/LS switch 4-pole 10kA C10A 0.3A A
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
In stock
€224.87
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 4P 10kA C-10A 300mA A Typ. Residual current circuit breaker according to DIN0664-20 / EN61009-1 with 4-pole circuit breaker for 400 V three-phase circuits and a residual current protection circuit in a compact housing. Contact protection according to IP2x according to DIN0106 Part 100, blue test button and residual current display. Easy individual removal from the phase busbar system. With VDE symbol. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device.

Property Value
Triggering characteristic: C
Rated current: 10 A
Rated residual current: 0.3 A
Rated voltage: 400 V
Frequency: 50 Hz
Number of poles (total): 4
Width in pitch units: 4
Fault current type: A
Installation depth: 70 mm
Surge current strength: 3 kA
Protection class (IP): IP20
Energy limitation class: 3
Overvoltage category: 3
Pollution degree: 2
Switching neutral conductor: no
Number of protected poles: 4
Type of voltage: AC
False tripping protection: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
Rated short-circuit breaking capacity Icn according to EN 61009-1: 10 kA
Shutdown characteristics: undelayed
With locking device: yes
Ambient temperature during operation: -25 to 40 °C
Connectable conductor cross-section, single-wire: 1 to 25 mm²
Connectable conductor cross-section, stranded: 1 to 16 mm²
Features
Shutdown characteristics
Rated short-circuit breaking capacity Icn according to EN 61009-1
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
False trigger protection
Residual current type
Frequency
With locking device
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Surge current strength
Ambient temperature during operation
Degree of contamination
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager AFX456D FI/LS switch 4-pole 10kA C6A 0.3A A
Hager AFX456D FI/LS switch 4-pole 10kA C6A 0.3A A
224.87
In stock
Hager AEX470C 4-pole 10kA C-20A 100mA A type circuit breaker
Hager AEX470C 4-pole 10kA C-20A 100mA A type circuit breaker
224.87
In stock
Hager AEX456C 4-pole 10kA C-6A 100mA A type circuit breaker
Hager AEX456C 4-pole 10kA C-6A 100mA A type circuit breaker
224.87
In stock
Hager AEX460C 4-pole 10kA C-10A 100mA A type circuit breaker
Hager AEX460C 4-pole 10kA C-10A 100mA A type circuit breaker
224.87
In stock
Hager AEX463C 4-pole 10kA C-13A 100mA A type circuit breaker
Hager AEX463C 4-pole 10kA C-13A 100mA A type circuit breaker
224.87
In stock
Hager AFX463D FI/LS switch 4-pole 10kA C13A 0.3A A
Hager AFX463D FI/LS switch 4-pole 10kA C13A 0.3A A
224.71
In stock