+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager CGA563D 2P 10kA 63A 500mA Type A residual current circuit breaker

Brand:HAGER
To compare
To favorites
SKU:410543
Hager CGA563D 2P 10kA 63A 500mA Type A residual current circuit breaker
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
In stock
€123.57
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Residual current circuit breaker 2-pole 10kA 63A 500mA type A. Residual current circuit breaker (FI) according to EN 61008-1, DIN EN 61008-2-1,0664 part 10 + 11, contact protection IP2x according to DIN0106 part 100. Suitable for the subsequent installation of additional equipment (installation without tools). Connection terminals with wire insertion protection, bi-connect terminals at the bottom, external blue test button. All products with symbol. Labeling option directly on the device.

Property Value
Rated voltage: 230 V
Rated current: 63 A
Rated residual current: 0.5 mA
Mounting type: DIN rail
Protection class (IP): IP20
Frequency: 50/60 Hz
Number of poles: 2
Width in modular spacing: 2
Selective type: no
Fault current type: A
Additional equipment possible: yes
Installation depth: 70 mm
Short-circuit strength (Icw): 10 kA
Surge current strength: 3 kA
Short-time delayed Type: no
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 4 kV
With locking device: yes
Ambient temperature during operation: -25 to 70 °C
Pollution degree: 2
Connectable conductor cross-section, stranded: 1 to 16 mm²
Connectable conductor cross-section Single-wire: 1 to 25 mm²
Features
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Rated residual current
Rated insulation voltage Ui
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Residual current type
Frequency
Short circuit strength (Icw)
Short-time delayed type
With locking device
Mounting type
Number of poles
IP protection)
Selective type
Surge current strength
Ambient temperature during operation
Degree of contamination
Additional equipment possible
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager UZ30D1 building block carrier 450mm
Hager UZ30D1 building block carrier 450mm
123.57
In stock
Hager LNH41443M4T NH fuse link NH4a gTr 400V 1000kVA 1443A
Hager LNH41443M4T NH fuse link NH4a gTr 400V 1000kVA 1443A
123.53
In stock
Hager FZ002N door right for cabinet H:500xW:550mm
Hager FZ002N door right for cabinet H:500xW:550mm
123.69
In stock
Hager KU73C40 eHZ connection cassette 4-pole
Hager KU73C40 eHZ connection cassette 4-pole
123.71
In stock
Hager MBN650 circuit breaker 3-pole+N B50A 4M 6kA
Hager MBN650 circuit breaker 3-pole+N B50A 4M 6kA
123.77
In stock
Hager KU73C50 eHZ connection cassette 4-pole
Hager KU73C50 eHZ connection cassette 4-pole
123.82
In stock
Hager UE31D1 building block universN 450x250mm
Hager UE31D1 building block universN 450x250mm
123.30
In stock