Hager HBB161H FI-Block x250 4-pole 160A Idn adjustable

Brand:HAGER
To compare
To favorites
SKU:303566
Hager HBB161H FI-Block x250 4-pole 160A Idn adjustable
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
In stock
€780.82
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

FI block size x250 4-pole 160A Idn adjustable. Electronic FI block in accordance with DIN EN 60947-2 for retrofitting to circuit breakers and load disconnectors. Built in a modular design for easy attachment to the circuit breaker or load disconnector. The residual current sensitivity and the tripping time can be set on the device. Both a mechanical and an electrical test button are available for tripping testing. Display (via LED on the device), remote display and tripping warning of I delta n at 50% are available.

Property Value
Max. Delay time: 1000 ms
Nominal voltage: 220 to 415 V
Delay time adjustable: yes
Rated residual current adjustable: yes
Nominal current: 160 A
Residual current type: other
Number of poles: 4
Rated residual current: 0.03 to 6 A
Surge current strength: 5 kA
Frequency: 50/60 Hz
Rated insulation voltage Ui: 500 V
Rated impulse voltage strength Uimp: 6 kV
Connectable conductor cross-section, single-wire: 35 to 185 mm²
Connectable conductor cross-section, stranded: 35 to 150 mm²
False tripping protection: yes
With locking device: yes
Protection class (IP): IP40
Pollution level: 3
Ambient temperature during operation: -25 to 70 °C
Features
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Rated residual current
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
False trigger protection
Residual current type
Frequency
With locking device
Nominal voltage
Rated current
Number of poles
IP protection)
Surge current strength
Ambient temperature during operation
Degree of contamination
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager FR72S universal IP55 SK II 1100x550x275mm cabinet
Hager FR72S universal IP55 SK II 1100x550x275mm cabinet
780.39
In stock
Hager HES160DC h3+ P160 3P3D 160A 70kA circuit breaker
Hager HES160DC h3+ P160 3P3D 160A 70kA circuit breaker
781.40
In stock
Hager FZ223D door uni. right IP54 1900x800mm SKI
Hager FZ223D door uni. right IP54 1900x800mm SKI
781.40
In stock
Hager FZ223SD door uni. right IP54 1900x800mm SKII
Hager FZ223SD door uni. right IP54 1900x800mm SKII
781.40
In stock
Hager FZ218D door uni. right IP54 1900x850mm SKI
Hager FZ218D door uni. right IP54 1900x850mm SKI
781.40
In stock
Hager FZ218SD door uni. right IP54 1900x850mm SKII
Hager FZ218SD door uni. right IP54 1900x850mm SKII
781.40
In stock
Hager ZAX009 festival base size 1 315x585x900
Hager ZAX009 festival base size 1 315x585x900
781.40
In stock
Hager LVDR800CPX double switch strip NH2 185mm
Hager LVDR800CPX double switch strip NH2 185mm
781.40
In stock