+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager HES160NC h3+ P160 3P3D 160A 70kA circuit breaker

Brand:HAGER
To compare
To favorites
SKU:431943
Hager HES160NC h3+ P160 3P3D 160A 70kA circuit breaker
Manufacturer
HAN
GTIN
Connection type main circuit
In stock
€1,632.61
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker h3+ P160 Energy 3P3D 160A 70kA CTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic trip can be set via the integrated OLED display, via a connectable door-mounted display or by a terminal with an Internet browser and WiFi using the configuration tool. The tripping curves for the overload current (Ir), the short-time delayed short-circuit current (Isd) and the undelayed short-circuit protection (Ii) as well as the time delay tr in the event of overload and the time delay tsd for short-time delayed short-circuit tripping can be set separately. In addition, the tripping curve can be adjusted inversely proportionally using an activatable I²t function between the short-circuit currents Ii and Isd and the short-time delayed and undelayed tripping time. The ready LED lights up green when the trigger is ready for use and flashes orange when an internal error is detected in the trigger. The LED for the overcurrent indication starts to flash red when I = 105% Ir and lights up red continuously when I > 112% Ir. The three different operating states can be identified by the position of the toggle (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a trigger button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be recognized and identified via the viewing window without opening the hinged cover. A potential-free alarm contact for the switch-off warning in the event of a risk of shutdown due to overload is integrated as standard. This is closed when I > 90% Ir (default value, changeable). This is indicated by an additional LED. It lights up orange when the contact is closed. An additional potential-free contact can be used in the trip unit for up to 12 individual alarms. The set trip curve can be tested and documented using an interface for a diagnostic and configuration tool. The integrated measuring technology measures all energies with an accuracy of class 1 according to IEC 61557-12. The partial energy storage can be reset. The h3+ Energy molded case circuit breaker can also be used to calculate power consumption values. These calculations can be made using a fixed or sliding interval that can be set from 5 to 60 minutes in steps of 1 minute. The calculation window can be synchronized with a signal sent by the communication system via the COM module. These consumption values can be used to create trends and forecasts based on this data. They provide basic data for developing a load profile. In addition, the h3+ Energy molded case circuit breakers measure the total harmonic distortion (THD) of the current and voltage.

Property Value
Rated continuous current Iu: 160 A
Type of connection for main circuit: Screw connection
Number of poles: 3
Device design: Built-in device, fixed installation technology
Position of the connection for main circuit: front
Degree of protection (IP): IP40
Setting range of the short-time delayed short-circuit release: 94.5 to 1600 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 70 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: yes
Motor drive integrated: no
Motor drive optional: no
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes
Features
Manufacturer
HAN
GTIN
Connection type main circuit
Design of the actuating element
Rated continuous current Iu
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz
Rated voltage
Setting range of the short-time delayed short-circuit release
Suitable for DIN rail mounting
Device type
DIN rail mounting optional
Integrated earth fault protection
Complete device with protection unit
With trip detector
Motor drive integrated
Motor drive optional
Number of poles
Position of the connection for main circuit
IP protection)
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager HMS041NC h3+ P160 4P4D 40A 50kA circuit breaker
Hager HMS041NC h3+ P160 4P4D 40A 50kA circuit breaker
1,632.61
In stock
Hager FG22KD series distribution board universal 2-field IP54
Hager FG22KD series distribution board universal 2-field IP54
1,635.35
In stock
Hager FR14E2 univ. IP55 SK I 1700x1050x275mm cabinet
Hager FR14E2 univ. IP55 SK I 1700x1050x275mm cabinet
1,639.44
In stock
Hager HMJ251DR h3 x630 TM ADJ 4P4D 250A 50kA circuit breaker
Hager HMJ251DR h3 x630 TM ADJ 4P4D 250A 50kA circuit breaker
1,639.45
In stock
Hager HMJ321DR h3 x630 TM ADJ 4P4D 320A 50kA circuit breaker
Hager HMJ321DR h3 x630 TM ADJ 4P4D 320A 50kA circuit breaker
1,639.45
In stock