Automatic changeover switch for mains generator 4x200A
Property | Value |
Number of poles: | 4 |
Rated operating power at AC-23, 400 V: | 90 kW |
Number of auxiliary contacts as normally open: | 1 |
Rated continuous current Iu: | 200 A |
Max. Rated operating voltage Ue at AC: | 415 V |
Design as EMERGENCY STOP device: | no |
Protection class (IP), front: | IP00 |
Connection type main circuit: | Cable clamp |
Device design: | Built-in device, fixed installation technology |
Design of the actuating element: | other |
Suitable for floor mounting: | yes |
Conditional Rated short-circuit current Iq: | 50 kA |
Motor drive integrated: | yes |
Suitable for front mounting 4-hole: | no |
Version as maintenance/repair switch: | yes |
Voltage release optional: | no |
Suitable for front mounting central: | no |
Suitable for intermediate installation: | no |
Suitable for Distribution board installation: | yes |
Version as main switch: | yes |
Version as safety switch: | yes |
Motor drive optional: | no |
Lockable: | yes |
Version as reversing switch: | yes |
Rated short-time withstand current Icw: | 12 kA |
Color of the actuating element: | other |
Rated operating voltage: | 380 to 415 V |
Switching capacity at 400 V: | 131 kW |
Rated continuous current at AC-21, 400 V: | 200 A |
Number of switches: | 1 |
Rated continuous current at AC-23, 400 V: | 200 A |
Protection class (NEMA): | other |
Features
Manufacturer
HAN
HIC420G
GTIN
3250613131777
Connection type main circuit
Cable clamp
Number of auxiliary contacts as normally open
1
Number of switches
1
Designed as main switch
Yes
Designed as an EMERGENCY STOP device
No
Designed as a safety switch
Yes
Designed as a maintenance/repair switch
Yes
Version as reversing switch
Yes
Design of the actuating element
Other
Conditional rated short-circuit current Iq
50kA
Rated operational power at AC-23, 400 V
90kW
Rated operating voltage
380 to 415 V
Rated continuous current Iu
200A
Rated continuous current at AC-21, 400 V
200A
Rated continuous current at AC-23, 400 V
200A
Rated short-time withstand current Icw
12kA
Color of the actuator
Other
Suitable for floor mounting
Yes
Suitable for front mounting 4-hole
No
Suitable for front mounting Central
No
Suitable for distribution board installation
Yes
Suitable for intermediate construction
No
Device type
Built-in device Fixed installation technology
Max. rated operating voltage Ue at AC
415V
Motor drive integrated
Yes
Motor drive optional
No
Number of poles
4
Switching capacity at 400 V
131kW
Protection class (IP), front
IP00
Protection class (NEMA)
Other
Voltage release optional
No
Lockable
Yes