+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager HMS041JC h3+ P160 4P4D 40A 50kA circuit breaker

Brand:HAGER
To compare
To favorites
SKU:432008
Hager HMS041JC h3+ P160 4P4D 40A 50kA circuit breaker
Manufacturer
HAN
GTIN
Connection type main circuit
In stock
€878.57
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker h3+ P160 LSI 4P4D N0-50-100% 40A 50kA CTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic trip can be set using a rotary latching switch. The tripping elements for the overload current (Ir), the short-time delayed short-circuit current (Isd) and the undelayed short-circuit protection (Ii) as well as the time delay tr for overload and the time delay tsd for short-time delayed short-circuit tripping can be set separately. In addition, the tripping curve can be adjusted inversely proportionally using an activatable I²t function between the short-circuit currents Ii and Isd and the short-time delayed and undelayed tripping time. The neutral conductor protection can be set to the OFF position, 50% of Ir and Isd or 100% of Ir and Isd using a control. The time delay remains the same as for tr and tsd. The ready LED lights up green when the release is ready for operation and flashes orange when an internal error is detected in the release. The LED for the overcurrent indicator starts flashing red when I = 105% Ir and lights up red continuously when I > 112% Ir. Another LED signals the overtemperature in the release unit. This lights up red when 105°C is exceeded internally. The three different operating states can be recognized by the position of the toggle (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The release button can be used to test the release mechanism and open the main contacts. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be seen and identified via the viewing window without opening the hinged cover. A potential-free alarm contact for the switch-off warning in the event of a risk of switch-off due to overload is integrated as standard. This is closed when I > 90% Ir. This is indicated by an additional LED. It lights up orange when the contact is closed. The set tripping curve can be tested and documented using an interface for a diagnostic and configuration tool.

Property Value
Rated continuous current Iu: 40 A
Type of connection for main circuit: Screw connection
Number of poles: 4
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Setting range of the short-time delayed short-circuit release: 21.9 to 400 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 50 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: no
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes
Features
Manufacturer
HAN
GTIN
Connection type main circuit
Design of the actuating element
Rated continuous current Iu
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz
Rated voltage
Setting range of the short-time delayed short-circuit release
Suitable for DIN rail mounting
Device type
DIN rail mounting optional
Integrated earth fault protection
Complete device with protection unit
With trip detector
Motor drive integrated
Motor drive optional
Number of poles
Position of the connection for main circuit
IP protection)
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager HMS101JC h3+ P160 4P4D 100A 50kA circuit breaker
Hager HMS101JC h3+ P160 4P4D 100A 50kA circuit breaker
878.57
In stock
Hager HNS161DC h3+ P160 4P4D 160A 40kA circuit breaker
Hager HNS161DC h3+ P160 4P4D 160A 40kA circuit breaker
878.57
In stock
Hager FP55TW wall cabinet IP54 SKI 800x1300x205mm
878.57
In stock
Hager FP04TN2 IP44 SKI 1550x1050x205mm wall cabinet
Hager FP04TN2 IP44 SKI 1550x1050x205mm wall cabinet
878.57
In stock
Hager FP55TW2 IP54 SKI 800x1300x205mm wall cabinet
Hager FP55TW2 IP54 SKI 800x1300x205mm wall cabinet
878.57
In stock
Hager HCW401AR h3+ P630 4 pole 400A load disconnector
Hager HCW401AR h3+ P630 4 pole 400A load disconnector
875.83
In stock
Hager HXW040HK x630/P630 24-48VDC AR from motor drive
Hager HXW040HK x630/P630 24-48VDC AR from motor drive
875.83
In stock