+351 934 234 451‬
Leave a call order
Адрес:
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Schedule:
Get route

Hager HMS101GC h3+ P160 4P4D 100A 50kA circuit breaker

Brand:HAGER
SKU:432019
Hager HMS101GC h3+ P160 4P4D 100A 50kA circuit breaker
Manufacturer
HAN
GTIN
Connection type main circuit
In stock
€702.03
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description

Circuit breaker h3+ P160 LSnI 4P4D N0-50-100% 100A 50kA CTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic trip can be set using a rotary latching switch. The tripping for the overload current (Ir) and the short-time delayed short-circuit current (Isd) can be set separately. The instantaneous tripping for the short-circuit current Ii is fixed. The neutral conductor protection can be set to the OFF position, 50% of Ir and Isd or 100% of Ir and Isd using a control. The time delay remains the same as for tr and tsd. A ready LED lights up green when the trip is ready for operation and flashes orange when an internal error is detected in the trip. Another LED starts to flash red when I = 105% Ir, and lights up red continuously when I > 112% Ir. The three different operating states can be recognized by the position of the toggle (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a release button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be recognized and identified via a viewing window without opening the hinged cover. The set tripping curve can be tested and documented using an interface for a diagnostic and configuration tool.

Property Value
Rated continuous current Iu: 100 A
Type of connection for main circuit: Screw connection
Number of poles: 4
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Setting range of the short-time delayed short-circuit release: 54.6 to 1000 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 50 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: no
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes
Features
Manufacturer
HAN
GTIN
Connection type main circuit
Design of the actuating element
Rated continuous current Iu
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz
Rated voltage
Setting range of the short-time delayed short-circuit release
Suitable for DIN rail mounting
Device type
DIN rail mounting optional
Integrated earth fault protection
Complete device with protection unit
With trip detector
Motor drive integrated
Motor drive optional
Number of poles
Position of the connection for main circuit
IP protection)
Reviews
No reviews yet — your comment may be first.
All reviews 0
general rating
×