+351 934 234 451‬
Leave a call order
Адрес:
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Schedule:
Get route

Hager HMW401NR h3+ P630 Energy 4P4D400A 50kA circuit breaker

Brand:HAGER
SKU:703869
Hager HMW401NR h3+ P630 Energy 4P4D400A 50kA circuit breaker
HAB
Manufacturer
HAN
GTIN
In stock
€2,594.66
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description

Circuit breaker h3+ P630 Energy 4P4D N0-50-100% 400A 50kA FTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The tripping curve of the electronic trip can be set using a rotary latching switch. The tripping elements for the overload current (Ir), the short-time delayed short-circuit current (Isd) and the undelayed short-circuit protection (Ii) as well as the time delay tr for overload and the time delay tsd for short-time delayed short-circuit tripping can be set separately. In addition, the tripping curve can be adjusted inversely proportionally using an activatable I²t function between the short-circuit currents Ii and Isd and the short-time delayed and undelayed tripping time. The ready LED lights up green when the trigger is ready for use and flashes orange when an internal error is detected in the trigger. The LED for the overcurrent indicator starts to flash red when I = 105% Ir, and lights up red continuously when I > 112% Ir. Another LED signals the overtemperature in the trigger unit. This lights up red when 105°C is exceeded internally. The three different operating states can be recognized by the position of the toggle (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a trigger button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be recognized and identified via a viewing window without opening the hinged cover. A potential-free alarm contact for the switch-off warning in case of danger of switch-off due to overload is integrated as standard. This is closed when I > 90% Ir. This is indicated by an additional LED. It lights up orange when the contact is closed. The set tripping curve can be tested and documented using an interface for a diagnostic and configuration tool.

Property Value
Rated continuous current Iu: 400 A
Type of connection for main circuit: Screw connection
Number of poles: 4
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Setting range of the short-time delayed short-circuit release: 218.4 to 4000 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 50 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: yes
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: no
Features
HAB
Manufacturer
HAN
GTIN
Connection type main circuit
Design of the actuating element
Rated continuous current Iu
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz
Rated voltage
Setting range of the short-time delayed short-circuit release
Suitable for DIN rail mounting
Device type
DIN rail mounting optional
Integrated earth fault protection
Complete device with protection unit
With trip detector
Motor drive integrated
Motor drive optional
Number of poles
Position of the connection for main circuit
IP protection)
Reviews
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products