Hager HNT101DR h3+ P250 4P4D 100A 40kA circuit breaker

Brand:HAGER
To compare
To favorites
SKU:432116
Hager HNT101DR h3+ P250 4P4D 100A 40kA circuit breaker
Manufacturer
HAN
GTIN
Connection type main circuit
In stock
€860.78
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker h3+ P250 TM ADJ 4P4D N0-100% 100A 40kA FTC. The molded case circuit breaker in accordance with DIN EN 60947-2 protects the electrical system and networks against overload and short circuit. The thermal release for the overload current (Ir) and the magnetic release for the instantaneous short circuit current (Ii) can be set separately. The neutral conductor protection can be activated using a controller. 0% or 100% of Ir can be set. The three different operating states can be identified by the position of the knob (ON = top, OFF = bottom, triggered = middle position). A device for locking the switching state in the ON or OFF position is integrated and can be used with a standard padlock without additional accessories. The trigger mechanism can be tested and the main contacts opened using a trigger button. A hinged cover with a captive quick-release screw allows access to the installation space for optional auxiliary contacts and other triggers. Integrated accessories can be seen and identified via the viewing window without opening the hinged lid.

Property Value
Rated continuous current Iu: 100 A
Type of connection for main circuit: Screw connection
Number of poles: 4
Device design: Built-in device, fixed installation technology
Position of connection for main circuit: front
Protection class (IP): IP40
Overload release current setting: 63 to 100 A
Setting range of the instantaneous short-circuit release: 600 to 1300 A
Rated voltage: 220 to 690 V
Rated short-circuit breaking current Icu at 400 V, 50 Hz: 40 kA
Suitable for DIN rail mounting: no
Design of the actuating element: toggle
Integrated earth fault protection: no
Motor drive integrated: no
Motor drive optional: yes
With trip detector: yes
Complete device with protection unit: yes
DIN rail mounting optional: yes
Features
Manufacturer
HAN
GTIN
Connection type main circuit
Design of the actuating element
Rated continuous current Iu
Rated ultimate short-circuit breaking current Icu at 400 V, 50 Hz
Rated voltage
Setting range of the instantaneous short-circuit release
Suitable for DIN rail mounting
Device type
DIN rail mounting optional
Integrated earth fault protection
Complete device with protection unit
With trip detector
Motor drive integrated
Motor drive optional
Number of poles
Position of the connection for main circuit
IP protection)
Overload release current setting
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager HBA160H FI-Block x160 3-pole 160A Idn adjustable
Hager HBA160H FI-Block x160 3-pole 160A Idn adjustable
861.06
In stock
Hager HNS160JC h3+ P160 3P3D 160A 40kA circuit breaker
Hager HNS160JC h3+ P160 3P3D 160A 40kA circuit breaker
859.41
In stock
Hager FP55SN2 IP44 SKII 800x1300x205mm wall cabinet
Hager FP55SN2 IP44 SKII 800x1300x205mm wall cabinet
862.14
In stock
Hager FWB42K4 AP field distributor 48PLE
Hager FWB42K4 AP field distributor 48PLE
862.51
In stock
Hager HES126DC h3+ P160 4P4D 125A 70kA circuit breaker
Hager HES126DC h3+ P160 4P4D 125A 70kA circuit breaker
863.51
In stock
Hager FP02SW2 SK II 1550x550x205mm wall cabinet
Hager FP02SW2 SK II 1550x550x205mm wall cabinet
863.51
In stock