Hager NBN416 circuit breaker 4-pole B16A 10kA 4M

Brand:HAGER
To compare
To favorites
SKU:157584
Hager NBN416 circuit breaker 4-pole B16A 10kA 4M
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
In stock
€111.38
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Circuit breaker 4-pole 10kA B characteristic 16A 4 modules. Circuit breaker according to EN 60898, IEC 60-947-2 touch protection IP2x according to DIN0106 Part 100 with symbol. Circuit breaker with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for the subsequent installation of additional equipment. Labeling option directly on the device and individual removal from the phase rail assembly by unlocking the quick-release top hat rail fastening.

Property Value
Triggering characteristic: B
Rated current: 16 A
Rated voltage: 400 V
Type of voltage: AC
Frequency: 50 to 60 Hz
Width in pitch units: 4
Number of poles (total): 4
Energy limitation class: 3
Additional equipment possible: yes
Overvoltage category: 3
Installation depth: 70 mm
Protection class (IP): IP20
Rated switching capacity Icn according to EN 60898 at 230 V: 10 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 30 kA
Rated switching capacity Icu according to IEC 60947-2 at 400 V: 15 kA
Rated switching capacity Icn according to EN 60898 at 400 V: 10 kA
Pollution degree: 2
Switching neutral conductor: no
Number of protected poles: 4
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 6 kV
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section, stranded: 1 to 25 mm²
Connectable conductor cross-section, single-wire: 1 to 35 mm²
Features
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icn according to EN 60898 at 400 V
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 400 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Energy limitation class
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager NCN250 circuit breaker 2-pole C50A 10kA 2M
Hager NCN250 circuit breaker 2-pole C50A 10kA 2M
111.38
In stock
Hager UG31T1 building block universN 450x250mm horizontal
Hager UG31T1 building block universN 450x250mm horizontal
111.40
In stock
Hager UC22TM2 300x500mm for load switch kit
Hager UC22TM2 300x500mm for load switch kit
111.30
In stock
Hager UM05B busbar connector 40mm universN 12x10mm 5-pole
Hager UM05B busbar connector 40mm universN 12x10mm 5-pole
111.11
In stock
Hager ZM35S busbar connector universZ 5-pole 12x10mm
Hager ZM35S busbar connector universZ 5-pole 12x10mm
111.69
In stock
Hager FZ882XF cover plate slotted 600x600mm
Hager FZ882XF cover plate slotted 600x600mm
111.76
In stock
Hager FZ884WF cover plate slotted 1100x400mm
Hager FZ884WF cover plate slotted 1100x400mm
111.76
In stock