+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager NDN140 circuit breaker 1-pole D40A 10kA 1M

Brand:HAGER
To compare
To favorites
SKU:305487
Hager NDN140 circuit breaker 1-pole D40A 10kA 1M
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
In stock
€38.44
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Miniature circuit breaker 1-pole 10kA D-characteristic 40A 1 module. Miniature circuit breaker according to EN 60898 IEC 60-947-2 contact protection IP2x according to DIN0106 Part 100 with symbol. LS with time-delayed thermal release for overload protection and electromagnetic release for short-circuit protection. Suitable for the subsequent installation of additional devices. Labelling option directly on the device and individual removal from the phase rail assembly by unlocking the quick-release top hat rail fastening.

Property Value
Triggering characteristic: D
Rated current: 40 A
Rated voltage: 400 V
Type of voltage: AC
Frequency: 50 to 60 Hz
Width in pitch units: 1
Number of poles (total): 1
Additional equipment possible: yes
Overvoltage category: 3
Installation depth: 70 mm
Protection class (IP): IP20
Rated switching capacity Icn according to EN 60898 at 230 V: 10 kA
Rated switching capacity Icu according to IEC 60947-2 at 230 V: 15 kA
Pollution degree: 2
Switching neutral conductor: no
Number of protected poles: 1
Rated insulation voltage Ui: 500 V
Rated impulse withstand voltage Uimp: 6 kV
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section, stranded: 1 to 25 mm²
Connectable conductor cross-section, single-wire: 1 to 35 mm²
Features
Manufacturer
HAN
GTIN
Connectable conductor cross-section solid
Connectable conductor cross-section stranded
Number of protected poles
Trigger characteristics
Rated insulation voltage Ui
Rated switching capacity Icn according to EN 60898 at 230 V
Rated switching capacity Icu according to IEC 60947-2 at 230 V
Rated voltage
Rated impulse withstand voltage Uimp
Rated current
Width in pitch units
Installation depth
Frequency
Switching neutral conductor
Number of poles (total)
IP protection)
Voltage type
Ambient temperature during operation
Degree of contamination
Additional equipment possible
Overvoltage category
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager MBN220 circuit breaker 2-pole B20A 6kA
Hager MBN220 circuit breaker 2-pole B20A 6kA
38.44
In stock
Hager MCS150 circuit breaker 1-pole C50A 6kA QC 1M
Hager MCS150 circuit breaker 1-pole C50A 6kA QC 1M
38.43
In stock
Hager SFB216 group switch 2-pole 16A center off
Hager SFB216 group switch 2-pole 16A center off
38.49
In stock
Hager MES-ILSE04 320x105 to flange 298x200 insect screen
Hager MES-ILSE04 320x105 to flange 298x200 insect screen
38.38
In stock
Hager US12A2 contact protection cover
Hager US12A2 contact protection cover
38.38
In stock