+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Send message to
WhatsApp
Send message to
Telegram
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Switches & Sockets
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager RFZ050D BEKA for 50 radio detectors, white control panel

Brand:HAGER
To compare
To favorites
SKU:707173
Hager RFZ050D BEKA for 50 radio detectors, white control panel
Operating voltage
HAB
Manufacturer
HAN
In stock
€1,399.42
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

BEKA control panel for 50 radio detectors, white. Bidirectional radio fire detection system for preventive fire protection for the construction and operation of day care facilities for children, small homes, accommodation facilities, hotels with more than 12 beds up to 60 beds for which no BMZ is required, as well as for residential facilities for seniors, disabled people or other special types of housing. The bidirectional radio transmission is transmitted using two separate radio bands with frequency interference in the 434 MHz range with 20 frequencies and in the 868 MHz range with 4 frequencies. A maximum of 64 automatic or manual devices can be controlled and evaluated in the 8 detection areas, which are integrated with automatic sensor head recognition and push-button learning procedures (max. 64 devices: 50 detectors, 14 radio indoor sirens or 10 repeaters). The control panel has the option of connecting alarm, fault, collective alarm reset with 3 switching inputs, day/night operation and has 4 relay and open collector switching outputs each for the external control of other display devices. The control panel checks the transmission path of the integrated detectors and components bidirectionally within 300 seconds and thus ensures a close-meshed transmission path check. Status/fault or alarm messages are shown on the control panel display in plain text with location/time information in combination with the 3-color display as optical and additional acoustic signal or forwarded to 8 defined recipients via SMS or email using the optional GSM module RFW066D. The last 1000 events can be viewed chronologically. During commissioning, the configuration is carried out manually on the control panel display or using the configuration tool, text entries and other settings as well as archiving can be imported or downloaded to the control panel via the USB or RS232 interface. After the initial installation is complete, an automatic overall check of the entire system is carried out and sent via USB interface, SD card or, optionally, with the GSM module, by email in the form of a handover/commissioning protocol. With the optional GSM module, the control panel can forward a status report on the degree of contamination, battery and system status of the individual integrated components by email to a defined recipient at the set maintenance request interval after confirmation by a trained person. In maintenance mode, the results of the maintenance can be transmitted via USB interface, SD card or, optionally, by email and saved separately and sent as a maintenance protocol. Access to the customer level is optionally possible via a PIN code to display the day/night function or to temporarily deactivate detection areas, as well as for basic settings of the customer level, resetting fault and alarm messages or optionally for forwarding the maintenance request by email or SMS. Access to the installer level is via a PIN code, whereby the main setting features of the system can only be configured or changed by the installer. The day/night setting, code change and other important configuration or setup settings can be made at the installer level. Note: The RFA400D emergency power battery is not included in the scope of delivery. Approval: DIN EN 54-2, DIN EN 54-4, DIN EN 54-25.

Property Value
Number of alarm groups: 8
Operating voltage: 230 V
Width: 220 mm
Bus-capable: no
Wireless connection: yes
Height: 325 mm
Integrated Dialer: no
With power supply: yes
Integrated emergency power supply: yes
External interface: yes
Depth: 88 mm
Mounting type: Structure
Number of detector addresses: 30
Current consumption: 50 mA
Addressable: no
Features
Operating voltage
HAB
Manufacturer
HAN
GTIN
Width
Height
Mounting type
Emergency power supply integrated
Power consumption
Depth
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager KEB734N1 unibarM size 4 for MCCB H3+ P250 4P tap-off box
Hager KEB734N1 unibarM size 4 for MCCB H3+ P250 4P tap-off box
1,398.54
In stock
Hager FP75SW2 SK II 1100x1300x205mm wall cabinet
Hager FP75SW2 SK II 1100x1300x205mm wall cabinet
1,397.23
In stock
Hager UF33Z1 transformer panel
Hager UF33Z1 transformer panel
1,397.23
In stock
Hager FG21LD series distribution board universal 1-field IP54
Hager FG21LD series distribution board universal 1-field IP54
1,391.75
In stock
Hager HES040NC h3+ P160 3P3D 40A 70kA circuit breaker
Hager HES040NC h3+ P160 3P3D 40A 70kA circuit breaker
1,408.18
In stock
Hager HET040NR h3+ P250 3P3D 40A 70kA circuit breaker
Hager HET040NR h3+ P250 3P3D 40A 70kA circuit breaker
1,408.18
In stock
Hager FL72SP polyester cabinet IP65 SKII 1150x600x300 UV res.
Hager FL72SP polyester cabinet IP65 SKII 1150x600x300 UV res.
1,390.51
In stock