+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Hager SPA800 T1+T2 3P Uc 350V Iimp 25kA combined arrester

Brand:HAGER
To compare
To favorites
SKU:770356
Hager SPA800 T1+T2 3P Uc 350V Iimp 25kA combined arrester
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Lightning surge current (10/350 µs)
Protection level
In stock
€719.82
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Combined arrester T1+T2 3P Uc 350V Iimp 25kA Up 1.5kV TNC remote signaling contact. Modular combined arrester consisting of a rotatable base part and plugged-in protection modules with remote signaling contact for monitoring device (potential-free change). Arrester type 1 and type 2 in accordance with DIN EN 61643-11 (VDE 0675-6-11). Simple, tool-free protection module change thanks to module locking system with function/defect display by marking in the viewing window. Encapsulated, non-blow-out spark gap design. Modular device according to DIN 43880, protection module coding, through terminals for all conductor connections.

Property Value
Protection level LN: 1.5 kV
Lightning impulse current (10/350 µs): 25 kA
Nominal discharge current (8/20): 25 kA
Highest continuous voltage AC: 350 V
Nominal voltage AC: 400 V
Protection level: 1.5 kV
Follow current extinguishing capacity: 25 kA
Mounting type: DIN rail TH35
Size: 6 TE
With remote signaling contact: yes
Blow-out: no
Signaling on the device: optical
Test class type 1: yes
Network type DC: no
Protection level N-PE: 1.5 kV
Suitable for outdoor use: no
Network type TT: no
Network type TN-CS: no
Integrated back-up fuse: no
Network type TN-S: no
Max. Conductor cross-section, rigid (single/multi-wire): 35 mm²
Max. Conductor cross-section flexible (fine-stranded): 35 mm²
Network type other: no
Network type TN: no
Network type TN-C: yes
Network type IT: no
Number of conductors (without earth): 3
Protection class (IP): IP20
Features
Max. conductor cross-section rigid (single/multi-wire)
Max. conductor cross-section flexible (fine-stranded)
Lightning surge current (10/350 µs)
Protection level
With remote signaling contact
Number of conductors (excluding earth)
Network form TT
Network type TN-S
Network form TN
Network type TN-C
Network type TN-C-S
Protection level L-N
Network type DC
Protection level N-PE
Integrated backup fuse
Network type IT
HAB
Manufacturer
HAN
GTIN
Size
Suitable for outdoor use
Highest continuous voltage AC
Mounting type
Nominal discharge current (8/20)
Nominal voltage AC
IP protection)
Signaling on the device
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Hager ZK52XP complete field WP univ. field heat pump BH5
Hager ZK52XP complete field WP univ. field heat pump BH5
719.82
In stock
Hager FR53E universal. IP55 SK I 800x800x275mm cabinet
Hager FR53E universal. IP55 SK I 800x800x275mm cabinet
720.27
In stock
Hager HMS160DC h3+ P160 3P3D 160A 50kA circuit breaker
Hager HMS160DC h3+ P160 3P3D 160A 50kA circuit breaker
721.19
In stock
Hager FL33S wall cabinet IP65 SKII 550x850x300
Hager FL33S wall cabinet IP65 SKII 550x850x300
718.45
In stock
Hager KEB772D1 unibarM size 2 LSS C/3P 63A CEE 5P tap-off box
Hager KEB772D1 unibarM size 2 LSS C/3P 63A CEE 5P tap-off box
721.36
In stock
Hager FWB64D field distributor 950x1050x161mm
Hager FWB64D field distributor 950x1050x161mm
721.75
In stock
Hager HBT100H P250 4P 100A Idn 30 mA to 6A FI-Block
Hager HBT100H P250 4P 100A Idn 30 mA to 6A FI-Block
722.56
In stock