+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Send message to
WhatsApp
Send message to
Telegram
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Switches & Sockets
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Janitza UMG 20CM residual current measuring device

Brand:Janitza
To compare
To favorites
SKU:890089
Janitza UMG 20CM residual current measuring device
Rated frequency
HAB
Manufacturer
HAN
In stock
€1,610.71
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Operating current and RCM measuring device UMG 20CM (Channel Meter) for DIN rail mounting Supply voltage 95V..240V (45-65Hz), 135V..340V DC, 4 voltage measuring inputs (LN: 10V-277Vrms, LL: 18V- 480Vrms, resolution 1V, 45Hz-65Hz), 20 current measuring inputs single-phase or three-phase, for measuring operating currents and RCM measurement Operating current (0-1 A, response current: 100 mA) 0 .. 600 A Connection via optional current transformers CT-6-20 700/1, CT20 700/1 and divisible current transformers STC20 3000/1 and differential current 1 .. 1000 mA (with load 16 A), Resolution 1 mA Connection via optional residual current transformers CT-6-20 700/1 and CT 20 700/1Measurement in 1-phase / multi-phase networks 1 ph, 2 ph, 3 ph, 4 ph and 20 x 1 phNetworks: TN, TT, and ITMeasurement in single-phase 3-wire systems up to max. 220V-440VMeasurement in single-phase 2-wire systems up to max. 220VVoltage measurement, measurement category 300V CATIII2 digital outputsAcknowledgement function on the device Polarity reversal for current transformers 50Hz filter function for residual currents Data storage: 768 KB Flash (31 days for 15min currents, active power, active energy and voltage) Interface: RS485Protocol: Modbus Accessories:3303310 Operating instructions

Features Value
Rated voltage: 10 to 480 V
Type of voltage for actuation: AC
Max. permissible response delay time: 650 s
Design of the electrical connection: Plug connection
Min. adjustable response delay time: 0.01 s
Response value current 1: 1 to 630000 mA
Rated frequency: 45 to 65 Hz
Response value current 2: 10 to 1000 mA
Width: 105 mm
Height: 90 mm
Depth: 73 mm
With removable Terminals: yes
Function: for mixed networks
Display of the residual current: yes
Fault storage possible: yes
Rated control supply voltage Us at AC 50 Hz: 90 to 276 V
Rated control supply voltage Us at AC 60 Hz: 90 to 276 V
Rated control supply voltage Us at DC: 90 to 276 V
Features
Rated frequency
HAB
Manufacturer
HAN
GTIN
Design of the electrical connection
Rated voltage
Rated control supply voltage Us at AC 50 Hz
Rated control supply voltage Us at AC 60 Hz
Rated control supply voltage Us at DC
Width
Function
Height
With removable clamps
Voltage type for actuation
Depth
No reviews yet — your comment may be first.
All reviews 0
general rating
Related Products
Janitza CT-AC/DC Type B+ 70 RCM residual current transformer
Janitza CT-AC/DC Type B+ 70 RCM residual current transformer
1,616.68
In stock
Janitza CT-AC RCM A310N residual current transformer
Janitza CT-AC RCM A310N residual current transformer
1,594.08
In stock
Janitza PROPHI 12TRS reactive power controller
Janitza PROPHI 12TRS reactive power controller
1,627.71
In stock
Janitza UMG 605-PRO 50-110VAC power quality analyzer
Janitza UMG 605-PRO 50-110VAC power quality analyzer
1,588.82
In stock
Janitza UMG 604 Option E-Max function activation code
1,579.87
In stock
Janitza Prophi 12TS reactive power controller
Janitza Prophi 12TS reactive power controller
1,645.16
In stock
Janitza UMG 605-PRO 24V (UL) Power Quality Analyzer
Janitza UMG 605-PRO 24V (UL) Power Quality Analyzer
1,542.45
In stock