Construction machinery, building sites, camping, event technology, agricultural equipment, connection and extension cables, indoor and outdoor use, durable under rough conditions thanks to resistant PUR sheath material, insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, wide temperature range for use in harsh climatic conditions, increased safety and visual perception thanks to the signal color of the outer sheath, tested properties, fine-wire, tinned copper conductor, core insulation made of TPE, outer sheath: PUR - color yellow, DESIGN: other sheath colors on request, cores stranded together, PRINT: other sheath print on request, Reg. No. 6583 up to 1.0 mm², Reg. No. 6584 from 1.5 mm², Suitable for use in fresh water up to 10 m water depth at a max. water temperature of +40 °C in accordance with EN 50565-2, Oil and drilling fluid resistant in accordance with IEC 61892-4, Appendix D, Abrasion-resistant and notch-resistant, Halogen-free and flame-retardant (IEC 60332-1-2), Cold-flexible down to -40 °C, Hydrolysis-resistant and microbe-resistant,
Property | Value |
Number of cores: | 5 |
Conductor nominal cross-section: | 0.75 mm² |
Sheath color: | yellow |
Outer diameter approx.: | 8.2 mm |
Conductor class: | Cl.5 = fine-wire |
Stranding element: | no |
Material of the core insulation: | other |
Core marking: | Color |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over Stranding: | without |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -40 to 90 °C |
Permissible Cable external temperature after installation without vibration: | -50 to 90 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 20 |
Conductor nominal cross-section (AWG): | 20 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use/free movement: | 82 mm |
Min. permissible bending radius, stationary use/fixed installation: | 32.8 mm |