in energy chains or mobile machine parts, use in measuring, control and regulation circuits, load circuits of electrical equipment in automation technology, conveyor and assembly lines, production lines, in all types of machines, outdoors not without UV protection and only when observing the temperature range, tried and tested, cost-effective variant, copper shielding to comply with EMC and protect against electromagnetic interference, additional robustness due to inner sheath, extra-fine strand made of bare copper wires (class 6), core insulation: PVC, cores stranded in layers with short lay lengths, PVC inner sheath, grey, copper braid, tinned, fleece wrapping, sheath made of PVC, grey (RAL 7001), when used in energy chains: please observe assembly guidelines appendix T3, core based on 0245/0285, sheath based on 0245/0285, low-adhesion surface, flame-retardant according to IEC 60332-1-2, designed for 5 million alternating bending cycles and travel distances of up to 10 meters, EMC compliant,
Property | Value |
Number of cores: | 7 |
Nominal conductor cross-section: | 2.5 mm² |
Sheath color: | gray |
Outer diameter approx.: | 15.8 mm |
Conductor class: | Class 6 = extra-fine wire |
Stranding element: | no |
Material of the core insulation: | Polyvinyl chloride (PVC) |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | braid |
Support element: | without |
Sheath material: | Polyvinyl chloride (PVC) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | no |
Permissible external cable temperature during assembly/handling: | 0 to 70 °C |
Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 14 |
Conductor nominal cross-section (AWG): | 14 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 118.5 mm |
Min. permissible bending radius, stationary use/fixed installation: | 63.2 mm |