in energy chains or mobile machine parts, especially in the wet areas of machine tools and transfer lines, in dry, damp or wet rooms with normal mechanical stress, use in measuring, control and regulation circuits, load circuits of electrical equipment in automation technology, tried and tested, versatile applications, durable under rough use due to resistant PUR sheath material, insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, extra-fine strand made of bare copper wires (class 6), core insulation: PVC, cores twisted in short lay lengths, fleece wrapping, sheath made of polyurethane, grey (RAL 7001), when used in energy chains: please observe assembly guidelines appendix T3, core based on 0245/0285, sheath based on 0245/0285, low-adhesion surface, increased oil resistance, flame retardant (IEC 60332.1.2), abrasion resistant and notch tough, designed for 5 million alternating bending cycles and travel distances of up to 10 meters,
Property | Value |
Number of cores: | 18 |
Nominal conductor cross-section: | 1 mm² |
Sheath color: | grey |
Outer diameter approx.: | 13.9 mm |
Conductor class: | Cl.6 = extra-fine-wire |
Stranding element: | no |
Material of the core insulation: | Polyvinyl chloride (PVC) |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | without |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | no |
Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 18 |
Conductor nominal cross-section (AWG): | 18 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 104.25 mm |
Min. permissible bending radius, stationary use/fixed installation: | 55.6 mm |