In energy chains or mobile machine parts, especially in the wet area of machine tools and transfer lines, in dry, damp or wet rooms with normal mechanical stress, use in measuring, control and regulation circuits, load circuits of electrical equipment in automation technology, conveyor and assembly lines, production lines, in all types of machines, tried and tested, versatile applications, durable in rough use thanks to resistant PUR sheath material, insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, ultra-fine strand made of bare copper wires (class 6), core insulation: PVC, cores twisted in short lay lengths, fleece wrapping, sheath made of polyurethane, grey (similar to RAL 7001), when used in energy chains: please observe assembly guidelines appendix T3, core and sheath based on an0245/0285, Low-adhesion surface, Increased oil resistance, Flame-retardant according to IEC 60332-1-2, Abrasion-resistant and notch-resistant,
| Property | Value |
| Number of cores: | 25 |
| Nominal conductor cross-section: | 1 mm² |
| Sheath color: | gray |
| Outer diameter approx.: | 16.4 mm |
| Conductor class: | Class 6 = extra-fine wire |
| Stranding element: | no |
| Material of the core insulation: | Polyvinyl chloride (PVC) |
| Core marking: | numbers |
| Protective conductor: | yes |
| Shield over stranding element: | without |
| Shield over stranding: | without |
| Support element: | without |
| Sheath material: | Polyurethane (PUR) |
| Torsion protection: | no |
| Halogen-free according to EN 60754-1/2: | no |
| Flame-retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Cold-resistant according to EN 60811-504+505+506: | yes |
| Oil-resistant according to EN 60811-404: | no |
| Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
| Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
| Nominal voltage U0: | 300 V |
| Nominal voltage U: | 500 V |
| AWG size: | 18 |
| Conductor nominal cross-section (AWG): | 18 kcmil |
| Specification of core insulation: | other |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | without |
| Smoke development class according to EN 13501-6: | without |
| Drip behavior class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Shape: | round |
| Min. permissible bending radius, flexible use with forced guidance: | 123 mm |
| Min. permissible bending radius, stationary use/fixed installation: | 65.6 mm |