Automated manufacturing processes require data cables with ever greater flexibility, stability and good shielding, Used in measuring, control and regulation circuits, assembly lines, production lines, in all types of machines, Overall shield minimizes electrical interference, Cable construction optimized for drag chain use, Tried and tested, Cost-effective variant, Fine-wire strand made of bare copper wires, Core insulation made of PVC, Copper braid, tinned, Outer jacket made of PVC Outer jacket color: gray (RAL 7001), Fleece wrapping, Based on 0812, For travel distances up to 10 m, When used in energy chains: Please observe assembly guidelines Appendix T3, Low-adhesion surface, Flame-retardant according to IEC 60332-1-2, Designed for 2 to 8 million alternating bending cycles in the energy chain,
| Property | Value |
| Number of cores: | 7 |
| Outer diameter approx.: | 7.4 mm |
| AWG cross-section: | 22 |
| Conductor class: | Class 6 = extra-fine wire |
| Stranding element: | no |
| Core marking: | Color |
| Shield over stranding element: | without |
| Category: | other |
| Flame retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Sheath color: | grey |
| Conductor nominal cross-section: | 0.34 mm² |
| Stranding: | Layers |
| Material of the core insulation: | Polyvinyl chloride (PVC) |
| Number of stranding elements: | 1 |
| Shield over stranding: | Braid |
| Conductor surface: | bare |
| Protective jacket: | no |
| Reinforcement: | no |
| Jacket material: | Polyvinyl chloride (PVC) |
| Halogen-free according to EN 60754-1/2: | no |
| Halogen-free according to IEC 60754-2: | no |
| Low smoke according to IEC 61034-2: | no |
| Oil resistant according to EN 60811-404: | no |
| Oil resistant according to IEC 60811-404: | no |
| Insulation integrity according to IEC 60331: | no |
| Function integrity: | no |
| Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
| Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
| Specification of core insulation: | other |
| Cable longitudinally watertight: | no |
| Cable transversely watertight: | no |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | none |
| Smoke development class according to EN 13501-6: | none |
| Drip behaviour class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Min. permissible bending radius, flexible use with forced guidance: | 55.5 mm |
| Min. permissible bending radius, stationary use/permanently installed: | 29.6 mm |
| Laying in the ground: | no |
| UV-resistant: | no |