in energy chains or mobile machine parts, especially in the wet area of machine tools and transfer lines, for use in assembly and placement machines, indoors and outdoors, conveyor and assembly lines, production lines, in machines of all kinds, allows faster movement sequences and thus increases the economic efficiency of machines, durable in rough use thanks to resistant PUR sheath material, insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, multi-standard validation reduces the variety of parts and saves costs, wide temperature range for use in climatically harsh environmental conditions, copper shielding to comply with EMC and protection against electromagnetic interference, ultra-fine strand made of bare copper wires (class 6), core insulation made of TPE, cores twisted together in extremely short lay lengths, fleece wrapping, sheath made of polyurethane, grey (RAL 7001), inner sheath made of TPE, copper braid, tinned, UL File No. E63634, When used in energy chains: Please observe assembly guidelines Appendix T3, USA: UL AWM Style 21576 plus VW-1 Canada: cUL AWM Style I/II A/B FT1, based on 0250 / 0285, low-adhesion surface, oil and drilling fluid resistant in accordance with IEC 61892-4, Appendix D, halogen-free and flame-retardant (IEC 60332-1-2), cold-flexible down to -40 °C, designed for 10 million alternating bending cycles and horizontal travel distances up to 100 meters, EMC compliant
Property | Value |
Number of cores: | 12 |
Nominal conductor cross-section: | 1 mm² |
Coat colour: | grey |
Outer diameter approx.: | 13.2 mm |
Conductor class: | Class 6 = extra fine wire |
Stranding element: | no |
Material of the core insulation: | other |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | Braid |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -40 to 80 °C |
Permissible Cable external temperature after installation without vibration: | -50 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 18 |
Conductor nominal cross-section (AWG): | 18 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 99 mm |
Min. permissible bending radius, stationary use/fixed installation: | 52.8 mm |