Connection cable between servo controller and motor, For use in assembly and placement machines, Especially in wet areas of machine tools and transfer lines, conveyor and assembly lines, production lines, in machines of all kinds, In energy chains or mobile machine parts, Indoors and outdoors, Allows faster movement sequences and thus increases the economic efficiency of machines, Copper braid to comply with EMC and shield against electromagnetic interference fields, Suitable for servo motor systems from well-known drive manufacturers, Longer cable lengths between converter and drive possible due to low-capacitance design, Insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, Wide temperature range for use in harsh climatic conditions, Fine-wire strand made of bare copper wires (class 6), Core insulation: polypropylene (PP), Individual article design: Power wires without or with one or two separately shielded control wire pairs together in short lay lengths stranded, power cores with control core triplet stranded together in short lay lengths, fleece wrapping, tinned copper braid, polyurethane (PUR) sheath, orange (RAL 2003). When used in energy chains: please note assembly guidelines Appendix T3, Reg. No. 8591 (0027925, ..926, ..927, ..930 in preparation) UL AWM Style 20234 cULus AWM I/II A/B, 1000V 80° FT1 CSA AWM I/II A, 1000V 80° FT1, UL File No. E63634, oil-resistant, halogen-free materials, flame retardancy: UL/CSA: VW-1, FT1 IEC/EN: 60332-1-2, abrasion-resistant and notch-resistant,
Property | Value |
Main conductor nominal cross-section: | 1 mm² |
Outer diameter approx.: | 11.7 mm |
Sheath color: | orange |
Number of main cores: | 4 |
Design: | round |
Material of the core insulation: | Polyolefins |
Main core identification: | Numbers |
Protective conductor: | yes |
Support element: | without |
Torsion protection: | no |
Sheath material: | Polyurethane (PUR) |
Flame retardant: | according to EN 60332-1-2 |
Perm. External cable temperature during assembly/handling: | -40 to 90 °C |
Perm. Cable external temperature after installation without vibration: | -50 to 90 °C |
Nominal voltage U: | 1 kV |
Oil resistant according to EN 60811-404: | yes |
AWG size main conductor: | 18 |
Main conductor nominal cross-section (AWG): | 18 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Min. permissible bending radius, flexible use with forced guidance: | 87.75 mm |
Min. permissible bending radius, stationary use/fixed installation: | 46.8 mm |