Automotive industry, industrial and machine tools, handling machines, In hose packages of articulated arm robots and for use in gantry robots, In energy chains or mobile machine parts, Space-saving due to small cable diameters, Durable in rough use due to resistant PUR sheath material, Insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, Wide temperature range for use in climatically harsh environmental conditions, Fine or ultra-fine strand made of bare copper wires, Core insulation made of TPE, Cores twisted in layers, Wrapping made of PTFE tape, Versions with additional core pair: 2 cores twisted to a pair, PTFE tape wrapping, Wrapping made of tinned copper wires, PUR inner sheath, Sheath made of polyurethane, black (similar to RAL 9005), When used in energy chains: Please observe assembly guidelines Appendix T3, For Travel distances up to 10 m, designed for up to 5 million torsion cycles, abrasion-resistant and notch-resistant, flexible at low temperatures, increased oil resistance, low-adhesion surface, flame-retardant,
| Property | Value |
| Number of cores: | 12 |
| Nominal conductor cross-section: | 1 mm² |
| Sheath color: | black |
| Outer diameter approx.: | 11.5 mm |
| Conductor class: | Class 5 = fine-wire |
| Stranding element: | no |
| Material of the core insulation: | other |
| Core marking: | numbers |
| Protective conductor: | yes |
| Shield over stranding element: | without |
| Shield over stranding: | without |
| Support element: | without |
| Sheath material: | Polyurethane (PUR) |
| Torsion protection: | no |
| Halogen-free according to EN 60754-1/2: | no |
| Flame-retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Cold-resistant according to EN 60811-504+505+506: | yes |
| Oil-resistant according to EN 60811-404: | yes |
| Permissible external cable temperature during assembly/handling: | -40 to 80 °C |
| Permissible Cable external temperature after installation without vibration: | -50 to 80 °C |
| Nominal voltage U0: | 300 V |
| Nominal voltage U: | 500 V |
| AWG size: | 18 |
| Conductor nominal cross-section (AWG): | 18 kcmil |
| Specification of core insulation: | other |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | without |
| Smoke development class according to EN 13501-6: | without |
| Drip behavior class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Shape: | round |
| Min. permissible bending radius, flexible use with forced guidance: | 172.5 mm |
| Min. permissible bending radius, stationary use/fixed installation: | 46 mm |