Automotive industry, industrial and machine tools, handling machines, In hose packages of articulated arm robots and for use in gantry robots, In energy chains or mobile machine parts, Space-saving due to small cable diameters, Durable in rough use due to resistant PUR sheath material, Insensitive to contact with many mineral oil-based lubricants, diluted acids, aqueous alkaline solutions and other chemical media, Wide temperature range for use in climatically harsh environmental conditions, Fine or ultra-fine strand made of bare copper wires, Core insulation made of TPE, Cores twisted in layers, Wrapping made of PTFE tape, Versions with additional core pair: 2 cores twisted to a pair, PTFE tape wrapping, Wrapping made of tinned copper wires, PUR inner sheath, Sheath made of polyurethane, black (similar to RAL 9005), When used in energy chains: Please observe assembly guidelines Appendix T3, For Travel distances up to 10 m, designed for up to 5 million torsion cycles, abrasion-resistant and notch-resistant, flexible at low temperatures, increased oil resistance, low-adhesion surface, flame-retardant,
Property | Value |
Number of cores: | 12 |
Nominal conductor cross-section: | 1 mm² |
Sheath color: | black |
Outer diameter approx.: | 11.5 mm |
Conductor class: | Class 5 = fine-wire |
Stranding element: | no |
Material of the core insulation: | other |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | without |
Support element: | without |
Sheath material: | Polyurethane (PUR) |
Torsion protection: | no |
Halogen-free according to EN 60754-1/2: | no |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | no |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -40 to 80 °C |
Permissible Cable external temperature after installation without vibration: | -50 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 18 |
Conductor nominal cross-section (AWG): | 18 kcmil |
Specification of core insulation: | other |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | without |
Smoke development class according to EN 13501-6: | without |
Drip behavior class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Shape: | round |
Min. permissible bending radius, flexible use with forced guidance: | 172.5 mm |
Min. permissible bending radius, stationary use/fixed installation: | 46 mm |