+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Lapp 0031330/100 UNITRONIC Li2YCY (TP) 2x2x0.5 RG100m data cable shielded

Brand:Lapp
To compare
To favorites
SKU:799634
Lapp 0031330/100 UNITRONIC Li2YCY (TP) 2x2x0.5 RG100m data cable shielded
Sheath material
Outer diameter approx.
Oil-resistant according to EN 60811-404
Category
In stock
€2.78
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

Is particularly suitable for cabling data systems with transmission rates of up to 10 megabits per second and is suitable for the RS422 and RS485 interfaces, for fixed and partially flexible installation, UNITRONIC® Li2YCYv (TP) with reinforced, black outer jacket (Yv) with at least 1.8 mm nominal minimum average wall thickness is designed for indoor and outdoor use as well as for applications where reinforced outer jackets prove to be advantageous, Use in dry or damp rooms, Signal, control and measuring cable, for the transmission of weak, sensitive signals and high bit rates, 7-wire stranded conductor (UNITRONIC® Li2YCY (TP) and UNITRONIC® Li2YCYv (TP) ) can be used for Maxi TERMI-POINT® wiring, Decoupling of circuits through TP structure (crosstalk and crosstalk effects), Overall shield minimizes electrical interference, 7-wire strand made of bare copper wires, core insulation made of polyethylene (PE), tinned copper braid, outer jacket made of PVC, outer jacket color: pebble gray (RAL 7032), twisted pair (TP) structure, based on 0812, flame retardant according to IEC 60332-1-2,

Property Value
Number of cores: 2
Outer diameter approx.: 8.5 mm
AWG cross-section: 22
Conductor class: Class 2 = stranded
Stranding element: Pairs
Core marking: Color
Shield over stranding element: without
Category: other
Flame retardant: according to EN 60332-1-2
Low smoke according to EN 61034-2: no
Sheath color: gray
Conductor nominal cross-section: 0.5 mm²
Stranding: other
Material of the core insulation: Polyolefins
Number of stranding elements: 2
Shield over stranding: Braid
Conductor surface: bare
Protective sheath: no
Reinforcement: no
Sheath material: Polyvinyl chloride (PVC)
Halogen-free according to EN 60754-1/2: no
Halogen-free according to IEC 60754-2: no
Low smoke according to IEC 61034-2: no
Oil-resistant according to EN 60811-404: no
Oil-resistant according to IEC 60811-404: no
Insulation integrity according to IEC 60331: no
Functional integrity: no
Permissible external cable temperature during assembly/handling: -5 to 70 °C
Permissible Cable external temperature after installation without vibration: -40 to 80 °C
Specification of core insulation: Polyethylene (PE)
Cable longitudinally watertight: no
Cable transversely watertight: no
Specification of sheath material: other
Fire behavior class according to EN 13501-6: none
Smoke development class according to EN 13501-6: none
Drip behaviour class according to EN 13501-6: without
Acid development class according to EN 13501-6: without
Min. permissible bending radius, flexible use/free movement: 127.5 mm
Min. permissible bending radius, stationary use/permanently installed: 51 mm
Laying in the ground: no
UV-resistant: no
Features
Sheath material
Outer diameter approx.
Oil-resistant according to EN 60811-404
Category
Conductor nominal cross section
HAB
Minimal order
Manufacturer
HAN
GTIN
Wire number
Functional preservation
Leader Class
Coat color
UV-resistant
No reviews yet — your comment may be first.
All reviews 0
general rating