Suitable for areas with a high density of people and large amounts of material assets that must be protected in the event of a fire, dry and damp rooms, for data processing, measurement and control technology, safety systems and as an electronic cable, stranded conductor (7-wire) can be used for Maxi TERMI-POINT® wiring (here only 0.34mm²), for use in public buildings, means of transport and industrial plants, low operating capacity due to polyolefin-based insulation mixture, halogen-free: in the event of a fire, protection of life and material assets due to low smoke density and low development of corrosive gases, small outer diameters despite the high number of cores, fine-stranded/multi-stranded (0.34 mm²) strand made of bare copper wires, core insulation made of a special halogen-free mixture, outer sheath made of a special halogen-free mixture, outer sheath color: pebble gray (RAL 7032), based on 0812, halogen-free according to IEC 60754-1, Low corrosiveness/acidity of the fire gases according to IEC 60754-2, Low toxicity of the fire gases according to EN 50305, Halogen-free with low smoke development (LSZH), Flame-retardant according to IEC 60332-1-2, Low smoke density according to IEC 61034-2,
| Property | Value |
| Number of cores: | 5 |
| Outer diameter approx.: | 5.7 mm |
| AWG cross-section: | 22 |
| Conductor class: | Cl.2 = stranded |
| Stranding element: | no |
| Core marking: | Color |
| Shield over stranding element: | without |
| Category: | other |
| Flame retardant: | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | yes |
| Sheath color: | gray |
| Conductor nominal cross-section: | 0.34 mm² |
| Stranding: | Layers |
| Material of the core insulation: | Polyolefins |
| Number of stranding elements: | 1 |
| Shield over stranding: | without |
| Conductor surface: | bare |
| Protective sheath: | no |
| Reinforcement: | no |
| Sheath material: | other |
| Halogen-free according to EN 60754-1/2: | yes |
| Halogen-free according to IEC 60754-2: | yes |
| Low smoke according to IEC 61034-2: | yes |
| Oil-resistant according to EN 60811-404: | no |
| Oil-resistant according to IEC 60811-404: | no |
| Insulation integrity according to IEC 60331: | no |
| Functional integrity: | no |
| Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
| Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
| Specification of core insulation: | other |
| Cable longitudinally watertight: | no |
| Cable transversely watertight: | no |
| Specification of sheath material: | other |
| Fire behavior class according to EN 13501-6: | Eca |
| Smoke development class according to EN 13501-6: | without |
| Drip behaviour class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Min. permissible bending radius, flexible use/free movement: | 57 mm |
| Min. permissible bending radius, stationary use/permanently installed: | 34.2 mm |
| Laying in the ground: | no |
| UV-resistant: | no |