Suitable for areas with a high density of people and large amounts of material that must be protected in the event of a fire, For data processing, measurement and control technology, safety systems and as an electronic cable, Stranded conductor (7-wire) can be used for Maxi TERMI-POINT® wiring (here only 0.34mm²), Use for computer systems, in MSR technology, office machines, scales - wherever shielded, halogen-free cables with small cross-sections are required., For use in public buildings, means of transport and industrial plants, Halogen-free: In the event of a fire, protection of life and material assets through low smoke density and low development of corrosive gases, Overall shield minimizes electrical interference, Low operating capacity due to polyolefin-based insulation mixture, Fine-stranded/multi-stranded (0.34 mm²) strand made of bare copper wires, Core insulation made of halogen-free special mixture, Copper braid, tinned, Outer jacket made of halogen-free special mixture Outer jacket color: pebble gray (RAL 7032), Based on 0812, Flame retardant according to IEC 60332-1-2, Halogen-free with low smoke development (LSZH), Halogen-free according to IEC 60754-1, Low corrosiveness/acidity of the fire gases according to IEC 60754-2, Low toxicity of the fire gases according to EN 50305, Low smoke density according to IEC 61034-2,
Property | Value |
Number of cores: | 25 |
Outer diameter approx.: | 10.9 mm |
AWG cross-section: | 24 |
Conductor class: | Cl.5 = fine-wire |
Stranding element: | no |
Core marking: | Color |
Shield over stranding element: | without |
Category: | other |
Flame-retardant: | according to EN 60332-1-2 |
Low smoke according to EN 61034-2: | yes |
Sheath color: | gray |
Conductor nominal cross-section: | 0.25 mm² |
Stranding: | Layers |
Material of the core insulation: | Polyolefins |
Number of stranding elements: | 1 |
Shield over stranding: | Braid |
Conductor surface: | bare |
Protective sheath: | no |
Reinforcement: | no |
Sheath material: | other |
Halogen-free according to EN 60754-1/2: | yes |
Halogen-free according to IEC 60754-2: | yes |
Low smoke according to IEC 61034-2: | yes |
Oil-resistant according to EN 60811-404: | no |
Oil-resistant according to IEC 60811-404: | no |
Insulation integrity according to IEC 60331: | no |
Functional integrity: | no |
Permissible external cable temperature during assembly/handling: | -5 to 70 °C |
Permissible Cable external temperature after installation without vibration: | -40 to 80 °C |
Specification of core insulation: | other |
Cable longitudinally watertight: | no |
Cable transversely watertight: | no |
Specification of sheath material: | other |
Fire behavior class according to EN 13501-6: | Eca |
Smoke development class according to EN 13501-6: | without |
Drip behaviour class according to EN 13501-6: | without |
Acid development class according to EN 13501-6: | without |
Min. permissible bending radius, flexible use/free movement: | 109 mm |
Min. permissible bending radius, stationary use/permanently installed: | 65.4 mm |
Laying in the ground: | no |
UV-resistant: | no |