Areas with high ambient temperatures and occasional mechanical stress, Typical areas of application - Steel, ceramics and steelworks - Bakery machines and industrial furnace construction - Electric motor industry - Sauna and solarium construction - Heat and heating elements - Lighting technology - Fan construction - Air conditioning technology - Galvanization technology, Longer service life than conventional silicone cables in rough use, Notch and tear-resistant silicone mixtures reduce damage caused by mechanical impact, Good flexibility simplifies installation in limited space, SiO2 ash structure remaining after flame exposure has insulating properties, By using special additives in EWKF silicone, it is sometimes possible to dispense with reinforced cable versions, Fine-wire, tinned copper conductor, Core insulation based on EWKF silicone, Cores twisted together, Notch-resistant outer jacket based on EWKF silicone, Color black, Based on EN 50525-2-83, Halogen-free (IEC 60754-1), corrosiveness of gases (IEC 60754-2), flame retardant (IEC 60332-1-2), good hydrolysis and UV resistance, resistant to a wide range of oils, alcohols, vegetable and animal fats and other chemical media, EWKF formula: tear - tear propagation - notch strength, ensure adequate ventilation, as the mechanical properties of silicone cables deteriorate prematurely from +100°C in the absence of air,
| Property | Value |
| Number of cores: | 3 |
| Nominal conductor cross-section: | 2.5 mm² |
| Sheath colour: | black |
| Outer diameter approx.: | 9.8 mm |
| Conductor class: | Cl.5 = fine-wire |
| Stranding element: | no |
| Material of the core insulation: | rubber |
| Core marking: | Color |
| Protective conductor: | yes |
| Shield over stranding element: | without |
| Shield over Stranding: | without |
| Support element: | without |
| Torsion protection: | no |
| Halogen-free according to EN 60754-1/2: | yes |
| Flame-retardant : | according to EN 60332-1-2 |
| Low smoke according to EN 61034-2: | no |
| Cold-resistant according to EN 60811-504+505+506: | yes |
| Oil resistant according to EN 60811-404: | no |
| Perm. Cable external temperature after installation without vibration: | -50 to 180 °C |
| Nominal voltage U0: | 300 V |
| Nominal voltage U: | 500 V |
| AWG size: | 14 |
| Conductor nominal cross-section (AWG): | 14 kcmil |
| Fire behavior class according to EN 13501-6: | without |
| Smoke development class according to EN 13501-6: | without |
| Drip behaviour class according to EN 13501-6: | without |
| Acid development class according to EN 13501-6: | without |
| Shape: | round |
| Min. permissible bending radius, flexible use/free movement: | 147 mm |
| Min. permissible bending radius, stationary use/permanently installed: | 39.2 mm |