In the field of temperature measurement or production process control in conjunction with a sheath thermocouple. The insulation materials must be selected according to the maximum ambient temperature at the connection head of the thermocouple., Conductor materials (alloys): Fe/CuNi (LX, JX) conductor alloys are identical to thermocouple alloys, NiCr/Ni (K, KX, KCA) K and KX version - conductor alloys are identical to thermocouple alloys KCA version: compensation alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys, PtRh/Pt (RCB, SCB) compensation alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys, Enables temperature measurement even in places where contactless temperature measurement is not possible or sensible, Space-saving and flexible, For detailed information, see Appendix T8 and data sheets, Structure abbreviations used: PVC: Polyvinyl chloride SIL: Silicone rubber GL: Glass silk FEP: Fluoroethylene propylene EGL: E-glass C: Copper shielding braid ST: Aluminum foil shield S: steel wire braid, construction example for PVC-PVC-S-PVC: - PVC core insulation - PVC inner sheath - steel wire braid - PVC outer sheath, image examples (from top to bottom): Fe/CuNi DIN 2x1, 5 PVC NiCr/Ni IEC 2x1, 5 GL-GL PtRh/Pt IEC 2x1, 5 GL-GL-S NiCr/Ni DIN 2x1, 5 SIL-GL NiCr/Ni DIN 2x1, 5 PVC-PVC PtRh/Pt DIN 2x1, 5 SIL-SIL Fe/CuNi IEC 2x1, 5 SIL-SIL-S NiCr/Ni IEC 2x1, 5 SIL PtRh/Pt IEC 2x1, 5 S, color coding DIN 43710 negative conductor and sheath: Fe/CuNi: blue NiCr/Ni: green PtRh/Pt: white Plus conductor: each red IEC 60 584 Plus conductor and sheath: Fe/CuNi: black NiCr/Ni: green PtRh/Pt: orange Minus conductor: each white,
Property | Value |
Conductor material conductor 2: | CuNi |
Conductor nominal cross-section: | 1.5 mm² |
Outer diameter approx.: | 10.3 mm |
Sheath color: | green |
Number of thermocouples: | 1 |
Material of the core insulation: | other |
Shield over stranding element: | without |
Shield over stranding: | without |
Reinforcement: | yes |
Sheath material: | Polyvinyl chloride (PVC) |
AWG cross-section: | 16 |
Specification of core insulation: | other |
Specification of sheath material: | other |
Min. permissible bending radius, flexible use/free movement: | 154.5 mm |
Min. permissible bending radius, stationary use/permanently installed: | 61.8 mm |
Fire behavior class according to EN 13501-6: | none |
Smoke development class according to EN 13501-6: | none |
Drip behavior class according to EN 13501-6: | none |
Acid development class according to EN 13501-6: | none |