+351 934 234 451‬
Rua Bartolomeo Dias 20, 8200-096 Albufeira, Portugal
Catalog
All categories
  • All categories
  • Smart home systems
  • Home and Garden
  • Electrics
  • Installation
  • Lamps and lights
  • Lamps and luminaires
  • PV systems and accessories
  • Other ranges
  • Accessories and Appliances
Catalog

Lapp 0167513/100 KN9L-SY NiCr/Ni KCA 2x1,5 IEC RG100m special cable

Brand:Lapp
To compare
To favorites
SKU:801408
Lapp 0167513/100 KN9L-SY NiCr/Ni KCA 2x1,5 IEC RG100m special cable
Sheath material
Outer diameter approx.
Conductor nominal cross section
HAB
In stock
€11.35
11
Shipping information
International shipping DHL
Рассчитываем стоимость доставки...
DPD
Рассчитываем стоимость доставки...
UPS
Рассчитываем стоимость доставки...
Description
Features
Reviews

In the field of temperature measurement or production process control in conjunction with a sheath thermocouple. The insulation materials must be selected according to the maximum ambient temperature at the connection head of the thermocouple., Conductor materials (alloys): Fe/CuNi (LX, JX) conductor alloys are identical to thermocouple alloys, NiCr/Ni (K, KX, KCA) K and KX version - conductor alloys are identical to thermocouple alloys KCA version: compensation alloys (for KCA: Fe/CuNi), not identical to thermocouple alloys, PtRh/Pt (RCB, SCB) compensation alloys (for RCB, SCB: Cu/CuNi) are not identical to thermocouple alloys, Enables temperature measurement even in places where contactless temperature measurement is not possible or sensible, Space-saving and flexible, For detailed information, see Appendix T8 and data sheets, Structure abbreviations used: PVC: Polyvinyl chloride SIL: Silicone rubber GL: Glass silk FEP: Fluoroethylene propylene EGL: E-glass C: Copper shielding braid ST: Aluminum foil shield S: steel wire braid, construction example for PVC-PVC-S-PVC: - PVC core insulation - PVC inner sheath - steel wire braid - PVC outer sheath, image examples (from top to bottom): Fe/CuNi DIN 2x1, 5 PVC NiCr/Ni IEC 2x1, 5 GL-GL PtRh/Pt IEC 2x1, 5 GL-GL-S NiCr/Ni DIN 2x1, 5 SIL-GL NiCr/Ni DIN 2x1, 5 PVC-PVC PtRh/Pt DIN 2x1, 5 SIL-SIL Fe/CuNi IEC 2x1, 5 SIL-SIL-S NiCr/Ni IEC 2x1, 5 SIL PtRh/Pt IEC 2x1, 5 S, color coding DIN 43710 negative conductor and sheath: Fe/CuNi: blue NiCr/Ni: green PtRh/Pt: white Plus conductor: each red IEC 60 584 Plus conductor and sheath: Fe/CuNi: black NiCr/Ni: green PtRh/Pt: orange Minus conductor: each white,

Property Value
Conductor material conductor 2: CuNi
Conductor nominal cross-section: 1.5 mm²
Outer diameter approx.: 10.3 mm
Sheath color: green
Number of thermocouples: 1
Material of the core insulation: other
Shield over stranding element: without
Shield over stranding: without
Reinforcement: yes
Sheath material: Polyvinyl chloride (PVC)
AWG cross-section: 16
Specification of core insulation: other
Specification of sheath material: other
Min. permissible bending radius, flexible use/free movement: 154.5 mm
Min. permissible bending radius, stationary use/permanently installed: 61.8 mm
Fire behavior class according to EN 13501-6: none
Smoke development class according to EN 13501-6: none
Drip behavior class according to EN 13501-6: none
Acid development class according to EN 13501-6: none
Features
Sheath material
Outer diameter approx.
Conductor nominal cross section
HAB
Minimal order
Manufacturer
HAN
GTIN
Coat color
No reviews yet — your comment may be first.
All reviews 0
general rating