public buildings, such as airports or train stations, intended for use within the framework of the European Construction Products Regulation (CPR), see catalog appendix T14, plant engineering, mechanical engineering, heating and air conditioning technology, event technology, especially where in the event of fire people, animals and valuable assets are at high risk from the consequences of a fire, Note: Use of cables of type AWM (Appliance Wiring Material) in industrial machines (USA) according to NFPA 79 Ed. 2015: see catalogue appendix table T29, easy handling and installation due to very flexible design, wide application area due to excellent product properties, validated for maritime use, fine-stranded wire made of bare copper wires, core insulation: halogen-free, jacket made of halogen-free special mixture grey (RAL 7001), cores twisted in layers, UL AWM style 21089, based on EN 50525-3-11, based on EN 50525-2-51, Germanischer Lloyd (GL) certificate no. 11 119-14 HH, flame-retardant according to IEC 60332-1-2 (flame spread on a cable), no fire propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame spread on vertical Cable or wire bundle), halogen-free according to IEC 60754-1 (proportion of gases containing halogen acid), corrosiveness of fire gases according to IEC 60754-2 (acidity level), low smoke density according to IEC 61034-2, oil-resistant according to EN 50363-4-1 (TM5) and UL OIL RES I and OIL RES II, UV and weather-resistant according to ISO 4892-2, ozone-resistant according to EN 50396
Property | Value |
Number of wires: | 25 |
Nominal conductor cross-section: | 1 mm² |
Sheath colour: | grey |
Outer diameter approx.: | 15 mm |
Conductor class: | Class 5 = fine-wire |
Stranding element: | no |
Material of the core insulation: | other |
Core marking: | numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over Stranding: | without |
Sheath material: | other |
Halogen-free according to EN 60754-1/2: | yes |
Flame-retardant: | according to EN 60332-3-24 |
Low smoke according to EN 61034-2: | yes |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -30 to 70 °C |
Permissible external cable temperature after assembly without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 18 |
Shape: | round |
Min. permissible bending radius, flexible use/free movement: | 150 mm |
Min. permissible bending radius, stationary use/fixed installation: | 60 mm |