public buildings such as airports or railway stations, Note: Use of cables of type AWM (Appliance Wiring Material) in industrial machines (USA) according to NFPA 79 Ed. 2015: see catalog appendix table T29, plant engineering, mechanical engineering, heating and air conditioning technology, especially where in the event of a fire both people, animals and valuable material assets are at high risk from the consequences of the fire, intended for use within the framework of the European Construction Products Regulation (CPR), see catalog appendix T58, easy to handle and install due to very flexible design, wide range of applications due to excellent product properties, validated for maritime use, fine-stranded strand made of bare copper wires, core insulation: halogen-free, inner jacket halogen-free, grey, copper braid, tinned, jacket made of halogen-free special mixture grey (RAL 7001), cores twisted in layers, UL AWM style 21089, based on EN 50525-3-11, based on EN 50525-2-51, Germanischer Lloyd (GL) certificate no. 11 119-14 HH, flame-retardant according to IEC 60332-1-2 (flame spread on a cable), no fire propagation according to IEC 60332-3-22 and IEC 60332-3-24 or IEC 60332-3-25 (flame spread on vertical cable or wire bundles), halogen-free according to IEC 60754-1 (proportion of gases containing halogenic acid), corrosiveness of the fire gases according to IEC 60754-2 (acidity level), low smoke density according to IEC 61034-2, oil-resistant according to EN 50363-4-1 (TM5) and UL OIL RES I and OIL RES II, UV and weather-resistant according to ISO 4892-2, ozone-resistant according to EN 50396
Property | Value |
Number of cores: | 12 |
Conductor nominal cross-section: | 2.5 mm² |
Sheath color: | gray |
Outer diameter approx.: | 17.9 mm |
Conductor class: | Class 5 = fine-wire |
Stranding element: | no |
Material of core insulation: | other |
Core marking: | Numbers |
Protective conductor: | yes |
Shield over stranding element: | without |
Shield over stranding: | Braid |
Sheath material: | other |
Halogen-free in accordance with EN 60754-1/2: | yes |
Flame-retardant: | in accordance with EN 60332-3-24 |
Low smoke in accordance with EN 61034-2: | yes |
Cold-resistant according to EN 60811-504+505+506: | yes |
Oil-resistant according to EN 60811-404: | yes |
Permissible external cable temperature during assembly/handling: | -30 to 70 °C |
Permissible External cable temperature after installation without vibration: | -40 to 80 °C |
Nominal voltage U0: | 300 V |
Nominal voltage U: | 500 V |
AWG size: | 14 |
Shape: | round |
Min. permissible bending radius, flexible use/free movement: | 268.5 mm |
Min. permissible bending radius, stationary use/fixed installation: | 107.4 mm |